Bone-Prosthesis Junction for Active Tendon Implants: A Biomechanical Comparison of 2 Fixation Techniques.

نویسندگان

  • Clarence B Toney
  • John R Owen
  • Imran A Khatri
  • Jennifer S Wayne
  • Charles L McDowell
چکیده

PURPOSE To study the biomechanical characteristics (percent stretch, stiffness, and ultimate load) of 2 distal fixation techniques for an active tendon implant used in the reconstruction of flexor tendons. METHODS We evaluated percent stretch after cyclical loading and at failure, stiffness during load-to-failure, and peak load of 28 bone-prosthesis junctions using cadaveric canine middle phalanges to study 2 fixation techniques: metal cleat and screw versus polyester cords secured with a knot. RESULTS The knot constructs displayed greater percent stretch during and following cyclical loading between 2 N and 50 N and at peak load. The screw construct showed greater stiffness from 50 N to 150 N during load-to-failure. Both fixation techniques failed at a mean peak load greater than 340 N. CONCLUSIONS Both fixation techniques for active tendon implants withstood loads seen with passive and active motion in the immediate postoperative period. Knot constructs displayed significant stretch during cyclical and load-to-failure testing, which would need to be compensated for during surgery. The screw constructs showed greater stiffness than the constructs secured with the surgeon's knot, but failure created an intra-articular fracture. CLINICAL RELEVANCE The results may aid the surgeon in choosing which fixation technique to use, during tensioning of cords, and in permitting active motion following surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proximal tendon-prosthesis junction for active tendon implants of the hand: a biomechanical comparison of 2 techniques.

PURPOSE To study the biomechanical characteristics (percent stretch, stiffness, and ultimate load) of 2 tendon-prosthesis techniques used to connect the proximal tendon stump to silicone active tendon implants used in reconstruction of flexor tendons. METHODS We evaluated percent stretch following cyclic loading and at failure, stiffness during load to failure, and ultimate load of 16 tendon-...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Tendon fixation in arthroscopic latissimus dorsi transfer for irreparable posterosuperior cuff tears: an in vitro biomechanical comparison of interference screw and suture anchors.

BACKGROUND The fixation of the tendon to the bone remains a challenging problem in the latissimus dorsi tendon transfer for irreparable cuff tears and can lead to unsatisfactory results. A new arthroscopic method of tendon to bone fixation using an interference screw has been developed and the purpose of this study was to compare its biomechanical properties to the ones of a standard fixation t...

متن کامل

Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading.

PURPOSE To mechanically test different reconstruction techniques of the anterior cruciate ligament (ACL) under incremental cyclic loading and to evaluate the impact of the level and method of graft fixation on tensile properties of each technique. TYPE OF STUDY In vitro biomechanical study. METHODS Four hamstring and 1 patellar tendon reconstruction techniques were performed on 40 young to ...

متن کامل

Numerical analysis of an osseointegrated prosthesis fixation with reduced bone failure risk and periprosthetic bone loss.

Currently available implants for direct attachment of prosthesis to the skeletal system after transfemoral amputation (OPRA system, Integrum AB, Sweden and ISP Endo/Exo prosthesis, ESKA Implants AG, Germany) show many advantages over the conventional socket fixation. However, restraining biomechanical issues such as considerable bone loss around the stem and peri-prosthetic bone fractures are p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of hand surgery

دوره 41 4  شماره 

صفحات  -

تاریخ انتشار 2016