Sinking and fit of abutment of locking taper implant system
نویسندگان
چکیده
STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location.
منابع مشابه
Abutment fracture and the technique Used to Remove the fracture portion of the Abutmet: Case Report
Abstract This clinical report presents a case of abutment fracture, due to occlusal overload, occurred with an implant-supported restoration on right mandibular first molar of a female patient. After 6 months of prosthetic reconstruction implants, the patient returned to the clinic due to the loss of implant crown. The fractured fragment of the abutment with the screw protec...
متن کاملEfficiency considerations for the purely tapered interference fit (TIF) abutments used in dental implants.
A tapered interference fit provides a mechanically reliable retention mechanism for the implant-abutment interface in a dental implant. Understanding the mechanical properties of the tapered interface with or without a screw at the bottom has been the subject of a considerable amount of studies involving experiments and finite element (FE) analysis. In this paper, approximate closed-form formul...
متن کاملPreload loss and bacterial penetration on different implant-abutment connection systems.
Preload loss can favor the occurrence of implant-abutment interface misfit, and bacterial colonization at this interface may lead to implant failure. The aim of this study was to evaluate the preload loss and bacterial penetration through the implant-abutment interface of conical and external hexagon connection systems subjected to thermal cycling and mechanical fatigue (TM). Four different imp...
متن کاملتحلیل بیومکانیکی پیچ و مخروط و آنالیز حساسیت شل شدن اباتمنت در ایمپلنتهای دندانی
Background and Aims: Different mechanisms have been developed for connecting abutment to implant. One of the most popular mechanisms is Tapered Integrated Screw (TIS), which is a Tapered Interference Fit (TIF) with a screw integrated at the bottom of that. The aim of this study was to investigate the mechanism of TIS and effective factors in employing TIS during design and implementation proces...
متن کاملمقایسه گپ مارژینال فریم ورکهای زیرکونیایی متکی بر ایمپلنت دو سیستم CAD/CAM
Background and Aims: Marginal accuracy is a crucial factor influencing the clinical long-term reliability of implant-supported fixed dental prostheses (FDPs). The aim of this in vitro study was to evaluate the marginal fit of three-unit zirconia bridge frameworks fabricated using two different computer-aided design (CAD)/ computer-aided manufacturing (CAM) systems (AmannGirrbach and Zirkonzahn...
متن کامل