Evaluation of periimplant bone neoformation using different scanning electron microscope methods for measuring BIC. A dog study

نویسندگان

  • José L. Calvo-Guirado
  • Antonio Aguilar-Salvatierra
  • Javier Guardia
  • Rafael Delgado-Ruiz
  • María P. Ramírez-Fernández
  • Cristina Pérez Sánchez
  • Gerardo Gómez-Moreno
چکیده

OBJECTIVES [corrected] The aim of this study was to determine which of three methods for measuring BIC (bone-to-implant contact), using vestibular and lingual scanning electron microscopy (SEM) for different implant systems at 15, 30 and 90 days post-surgery was the most precise. An elemental analysis with SEM was used to evaluate neoformed bone composition for three implant systems at the same study times. MATERIAL AND METHODS 36 implants were placed in eighteen Beagle dogs mandible about one year old and weighing approximately 12-13 kg in order to evaluate bone apposition to three different implant surfaces. It was used the third and fourth premolar and first molar distal sockets in both quadrants of the mandible (3P3, 4P4 and 1M1). Teeth were hemi-sected and the distal roots were removed. The specimens were prepared for histological examination and each section surface was stained using Masson's trichrome and hematoxylin and eosin stains. BIC evaluations were performed by the three methods, BIC I (the quantity of mineralized bone in direct contact with the implant's titanium surface across the entire threaded area); BIC II (along a line that passes from apex to apex of the implant threads); BIC III (both in areas around and above the threads and in between threads). RESULTS Both BIC and bone content were analyzed for all implants placed in P3, P4 y M1 alveoli on both, the buccal and palatine sides (elemental analysis quantified Ca, P, O and C). It was seen it was only at the ninety-day mark that high percentages of calcium were present. CONCLUSIONS This study suggest that BIC III evaluation is the most certain method for establishing the quantity of bone formed as the BIC area. Key words:Bone-to-impant contact, dogs, extraction socket, implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new standardized-automatic method for bone-to-implant contact histomorphometric analysis based on backscattered scanning electron microscopy images.

AIM To establish an image analysis procedure for measuring the bone-to-implant contact (BIC) by a systematic non-subjective approach based on backscattered scanning electron microscopy (BS-SEM) images. MATERIAL AND METHODS A total of 36 dental implants (9 mm length, Ø 4.0 mm with a SBM surface) were implanted in six beagle dog mandibles. The implants were removed after 1, 2, 4, 6, and 8 weeks...

متن کامل

The comparison between implant stability quotient and bone-implant contact revisited: an experiment in Beagle dog.

BACKGROUND Resonance frequency analysis (RFA) is applied clinically for the assessment of implant stability, and the relevance of this application is widely accepted. However, the relationship between resonance frequency (RF) and other parameters of implant stability, such as the histomorphometrical bone-to-implant contact (BIC) parameter, has become controversial in the last decade. OBJECTIV...

متن کامل

EVALUATION OF ANTIBACTERIAL PROPERTIES OF POLYLACTIC ACID-POLYCAPROLACTONE-CONTAINING HYDROXYAPATITE AND ZINC OXIDE NANOPARTICLES IN HARD TISSUE ABSORBABLE SCAFFOLDS

Today, many people need to use bone grafts and implants because of damage to bone tissue. Due to the stimulation of the immune system after implantation, infection at the operation site is very common, which causes swelling and pain in the operation area. The use of zinc oxide nanoparticles reduces infection at the operation site and reduces the patient's need for antibiotics. In the present st...

متن کامل

Early bone healing around implant surfaces treated with variations in the resorbable blasting media method. A study in rabbits.

OBJECTIVE this study aimed to histomorphologically and histomorphometrically evaluate the in vivo response to three variations in the resorbable blasting media (RBM) surface processing in a rabbit femur model. STUDY DESIGN screw root form implants with 3.75 mm in diameter by 8 mm in length presenting four surfaces (n=8 each): alumina-blasted/acid-etched (AB/AE), bioresorbable ceramic blasted ...

متن کامل

FGF‐2 promotes initial osseointegration and enhances stability of implants with low primary stability

OBJECTIVES The aim of this study was to examine the effect of basic fibroblast growth factor (FGF-2) on osseointegration of dental implants with low primary stability in a beagle dog model. MATERIALS AND METHODS Customized titanium implants that were designed to have low contact with the existing bone were installed into the edentulous mandible of beagle dogs. To degrade the primary stability...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012