GPS source solution of the 2004 Parkfield earthquake
نویسندگان
چکیده
We compute a series of finite-source parameter inversions of the fault rupture of the 2004 Parkfield earthquake based on 1 Hz GPS records only. We confirm that some of the co-seismic slip at shallow depth (<5 km) constrained by InSAR data processing results from early post-seismic deformation. We also show 1) that if located very close to the rupture, a GPS receiver can saturate while it remains possible to estimate the ground velocity (~1.2 m/s) near the fault, 2) that GPS waveforms inversions constrain that the slip distribution at depth even when GPS monuments are not located directly above the ruptured areas and 3) the slip distribution at depth from our best models agree with that recovered from strong motion data. The 95(th) percentile of the slip amplitudes for rupture velocities ranging from 2 to 5 km/s is ~55 ± 6 cm.
منابع مشابه
Updating HTDP for two recent earthquakes in California
This paper describes the National Geodetic Survey (NGS) process for selecting and validating models for two recent earthquakes prior to their inclusion in the Horizontal Time Dependent Positioning software (HTDP v 2.9), the 28 September 2004 Parkfield, California earthquake with a magnitude of 6.0 and the 22 December 2003 San Simeon, California earthquake with a magnitude of 6.5 . The process o...
متن کاملChange of apparent segmentation of the San Andreas fault around Parkfield from space geodetic observations across multiple periods
[1] Sequences of earthquakes are commonly represented as a succession of periods of interseismic stress accumulation followed by coseismic and postseismic phases of stress release. Because the recurrence time of large earthquakes is often greater than the available span of space geodetic data, it has been challenging to monitor the evolution of interseismic loading in its entire duration. Here ...
متن کاملSpatially variable fault friction derived from dynamic modeling of aseismic afterslip due to the 2004 Parkfield earthquake
[1] We investigate fault friction from dynamic modeling of fault slip prior to and following the Mw 6.0 earthquake which ruptured the Parkfield segment of the San Andreas Fault in 2004. The dynamic modeling assumes a purely rate-strengthening friction law, with a logarithmic dependency on sliding rate: m 1⁄4 m þ a b ð Þ ln v v . The initial state of stress is explicitly taken into account, and ...
متن کاملThirty-Five-Year Creep Rates for the Creeping Segment of the San Andreas Fault and the Effects of the 2004 Parkfield Earthquake: Constraints from Alignment Arrays, Continuous Global Positioning System, and Creepmeters
We present results from differential Global Positioning System (GPS) surveys of seven alignment arrays and four continuous GPS sites along the creeping segment of the San Andreas fault. Surveys of four alignment arrays from the central creeping segment yield 33to 36-year average minimum slip rates of 21–26 mm/yr. These rates are consistent with previous alignment array surveys spanning a 10-yea...
متن کاملAnisotropy in the Shallow Crust Observed around the San Andreas Fault Before and After the 2004 M 6 . 0 Parkfield Earthquake
Local seismic arrays were deployed at two locations along the San Andreas fault (SAF) near Parkfield, California, before and after the 2004 M 6.0 Parkfield earthquake. Using local earthquakes we determine the anisotropic field within 1– 2 km of the main trace of the SAF at the two array locations separated by 12 km. The initial array, near the SAFOD site, was deployed for six weeks in October a...
متن کامل