Internal Mammary Arterial Injury from Lead Extraction: A Clinically Subtle yet Important Complication of Implantable Device Removal
نویسندگان
چکیده
Percutaneous implantable device extraction has increased in recent years and is associated with small but significant risk. Arteriovenous fistula formation is an uncommon complication of this procedure. We report two cases where lead extraction was complicated by an arteriovenous fistula between the left internal mammary artery and the left brachiocephalic vein. In both cases, the patients were asymptomatic and the presence of a continuous murmur in the left subclavicular region led to the appropriate diagnosis. These were successfully treated with coil embolization. Auscultation around prior extraction sites should be routinely done to aid in the diagnosis of this potentially harmful complication.
منابع مشابه
Removal of Misplaced Left Ventricular Single Lead Pacemaker in a Patient Presenting with Recurrent Transient Ischemic Attacks
HINOJOS A, ILG K. Removal of Misplaced Left Ventricular Single Lead Pacemaker in a Patient Presenting with Recurrent Transient Ischemic Attacks. Spartan Med. Res. J. Vol. 2, No. 1, pp. 64-73, 2017. CONTEXT: Over 200,000 cardiac electronic implantable devices are annually placed in individuals living within the United States. Complications from this procedure can range up to 12%. Inadvertent lea...
متن کاملProphylactic lead extraction at implantable cardioverter-defibrillator generator change.
BACKGROUND Current implantable cardiac devices have a finite battery life of ≈3 to 7 years for implantable cardioverter-defibrillators. It is current practice to reuse all properly functioning intravascular leads. We tested the hypothesis that a strategy of prophylactic lead removal at the time of device change would be superior under some conditions to the current practice of lead reuse. MET...
متن کاملSalvage of focally infected implantable cardioverter-defibrillator system by in situ hardware sterilization
Introduction Cardiovascular implantable electronic device (CIED)-related infections have increased in frequency over the past 2 decades out of proportion to the rise in device implantations. This has occurred despite an improvement in technology, which includes smaller device profiles, improvement in battery life, prepectoral systems, and greater operator experience. Much of what is driving thi...
متن کاملSubacute Arterial Bleeding After Simultaneous Mastopexy and Breast Augmentation with Implants
Breast augmentation with implants is one of the most commonly performed plastic surgery procedures. The goal of the operation is to increase the size, shape or fullness of the breast. It is accomplished by placing silicone, saline or alternative composite breast implants under the chest muscles, fascia or the mammary gland. This type of operation is no exception concerning the occurrence of com...
متن کاملIdentification and management of right ventricular perforation using pacemaker and cardioverter-defibrillator leads: A case series and mini review
Right ventricular perforation is a rare but serious complication of permanent pacemaker and implantable cardioverter-defibrillator implantation, with a reported prevalence rate of 0.1-6%. Generally, there is a high incidence of asymptomatic lead perforation with otherwise normal function. Some patients present with a stabbing chest pain and shortness of breath or pacemaker malfunction. However,...