Control of Biofilm Formation and Inorganic Particle Accumulation on Reverse Osmosis Membrane by Hypochlorite Washing
نویسندگان
چکیده
Reverse osmosis (RO) membranes have been widely used for desalination to purify water for drinking and other purposes. Although at present most RO membranes have no resistance to chlorine, chlorine-resistant membranes are being developed. Therefore, direct chlorine treatment or chlorine washing will be an option in preventing biofouling on chlorine-resistant membranes. Furthermore, if particle accumulation control is possible by using chlorine washing, expensive pretreatment for particle removal can be removed or simplified. The objective of this study was to determine the effective hypochlorite washing condition required for controlling biofilm formation and inorganic particle accumulation on RO membrane in a continuous flow channel with RO membrane and spacer. In this study, direct chlorine washing was done by soaking fouled RO membranes in hypochlorite solution and fluorescence intensity was used to quantify biofilm on the membrane surface. After 48 h of soaking the membranes in high fouling potential waters, the fluorescence intensity decreased to 0 from 470 using the following washing conditions: 10 mg/L chlorine concentration, 2 times/d washing interval, and 30 min washing time. The chlorine concentration required to control biofilm formation decreased as the chlorine concentration (0.5–10 mg/L), the washing interval (1–4 times/d), or the washing time (1–30 min) increased. For the sample solutions used in the study, 10 mg/L chlorine concentration with 2 times/d interval, and 5 min washing time was required for biofilm control. The optimum chlorine washing conditions obtained from soaking experiments proved to be applicable also in controlling biofilm formation in continuous flow experiments. Moreover, chlorine washing employed in controlling biofilm with suspended particles resulted in lower amounts of organic (0.03 mg/cm) and inorganic (0.14 mg/cm2) deposits on the membrane than that for sample water without chlorine washing (0.14 mg/cm2 and 0.33 mg/cm2, respectively). The amount of biofilm formed was 79% controlled by continuous washing with 10 mg/L of free chlorine concentration, and the inorganic accumulation amount decreased by 58% to levels similar to that of pure water with kaolin (0.17 mg/cm2) as feed water. These results confirmed the acceleration of particle accumulation due to biofilm formation, and that the inhibition of biofilm growth can almost completely reduce further particle accumulation. In addition, effective hypochlorite washing condition which can control both biofilm formation and particle accumulation could be achieved. Keywords—Biofouling control, hypochlorite, reverse osmosis, washing condition optimization. M. Ohno is with the Environmental Research and Management Center, Hiroshima University, Higashi-hiroshima, Hiroshima 739-8513 Japan (phone: +81-82-424-6195; e-mail: [email protected]). Cervinia Manalo and Satoshi Nakai are with the Department of Chemical Engineering, Hiroshima University, Higashi-hiroshima, Hiroshima 739-8527 Japan (e-mail: [email protected], [email protected]). Tetsuji Okuda and Wataru Nishijima are with the Environmental Research and Management Center, Hiroshima University, Higashi-hiroshima, Hiroshima 739-8513 Japan (e-mail: [email protected], [email protected]).
منابع مشابه
Performance and Structure of Thin Film Composite Reverse Osmosis Membranes Prepared by Interfacial Polymerization in the Presence of Acid Acceptor
During interfacial polymerization (IP) reaction between m-phenylenediamine (MPDA) and trimesoyl chloride (TMC), a by-product, i.e. hydrochloric acid can produce. This produced acid diffuses back in aqueous phase and protonates MPDA and reduces its reactivity that results in lowering of polymer yield and performance of membrane. Further, for getting consistency in reverse...
متن کاملInvestigation of the Effect of Copolymer Antiscalant on TDS Removal Efficiency in Reverse Osmosis Membrane
Background & objectives: Nowadays, according to membrane-based filtration processes; the use of substances such as antiscalants that prevents the formation of deposits during the treatment process, is very important from industrial point of view. This study aimed to synthesize styrene-maleic anhydride copolymer (PSMA) using the radical polymerization method and to investigate the factors and pa...
متن کاملEffect of Organoclay on the Performance of Reverse Osmosis Membrane
This study investigated the effect of Cloisite15A (C15A) organoclay in the substrate layer on the performance of reverse osmosis (RO) membranes. The substrate of the RO membranes was modified using different loading of C15A (ranging from 0.3 - 0.7 wt%) within polysulfone (PSf) substrate and the polyamide (PA) selective layer was formed on the top. Effect of the modified substrate layer on the w...
متن کاملTreatment of Phenolic Wastewaters by a Domestic Low-Pressure Reverse Osmosis System
In this paper, the removal of phenol by using aqueous solution in a low pressure reverse osmosis membrane was investigated. The effect of feed pressure, feed concentration, feed flow rate and feed pH on phenol rejection was investigated. The results showed that feed pH is the most affective parameter on the phenol rejection. Rejection of phenol increased with increasing pH from 2 to 10 under th...
متن کاملComparison the performance of different reverse osmosis membrane modules by CFD modeling
Reverse osmosis is a commonly used process in water desalination. Due to the scarcity of freshwater resources and wastewater problems, a lot of theory and experimental studies have been conducted to optimize this process. In the present study, the performance of reverse osmosis membrane module of salt–water separation was simulated based on computational fluid dynamics technique and solution-di...
متن کامل