Imaging of cochlear tissue with a grating interferometer and hard X-rays.
نویسندگان
چکیده
This article addresses an important current development in medical and biological imaging: the possibility of imaging soft tissue at resolutions in the micron range using hard X-rays. Challenging environments, including the cochlea, require the imaging of soft tissue structure surrounded by bone. We demonstrate that cochlear soft tissue structures can be imaged with hard X-ray phase contrast. Furthermore, we show that only a thin slice of the tissue is required to introduce a large phase shift. It is likely that the phase contrast image of the soft tissue structures is sufficient to image the structures even if surrounded by bone. For the present set of experiments, structures with low-absorption contrast have been visualized using in-line phase contrast imaging and a grating interferometer. The experiments have been performed at the Advanced Photon Source at Argonne National Laboratories, a third generation source of synchrotron radiation. The source provides highly coherent X-ray radiation with high-photon flux (>10(12) photons/s) at high-photon energies (5-70 keV). Radiographic and light microscopy images of the gerbil cochlear slice samples were compared. It has been determined that a 20-mum thick tissue slice induces a phase shift between 1/3pi and 2/3pi.
منابع مشابه
Hard-X-ray dark-field imaging using a grating interferometer.
Imaging with visible light today uses numerous contrast mechanisms, including bright- and dark-field contrast, phase-contrast schemes and confocal and fluorescence-based methods. X-ray imaging, on the other hand, has only recently seen the development of an analogous variety of contrast modalities. Although X-ray phase-contrast imaging could successfully be implemented at a relatively early sta...
متن کاملX-ray phase imaging with a grating interferometer.
Using a high-efficiency grating interferometer for hard X rays (10-30 keV) and a phase-stepping technique, separate radiographs of the phase and absorption profiles of bulk samples can be obtained from a single set of measurements. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index, with a spatial resolution down to a few microns. The method is m...
متن کاملSubnanoradian X-ray phase-contrast imaging using a far-field interferometer of nanometric phase gratings
Hard X-ray phase-contrast imaging characterizes the electron density distribution in an object without the need for radiation absorption. The power of phase contrast to resolve subtle changes, such as those in soft tissue structures, lies in its ability to detect minute refractive bending of X-rays. Here we report a far-field, two-arm interferometer based on the new nanometric phase gratings, w...
متن کاملAn Overview of Technological Developments in Medical Applications of X-Rays and Radioactivity
The years 1895 to 1898 were momentous for their impact on health and human well beings. First, Wilhelm Roentgen noted a glowing fluorescent screen, caused by invisible rays. This event subsequently led to the discovery of X-rays in 1895, and thus the birth of the “atomic ageâ€. Next Becquerel’s investigations of these mysterious rays led to his experiments with uranium salt crystals. He th...
متن کاملX-ray phase contrast imaging using a grating interferometer
the differences in the absorption cross section of the constituents of the object. The technique yields excellent results where highly absorbing structures, e.g., bones, are embedded in a matrix of relatively weakly absorbing material, e.g., the surrounding tissue of the human body. However, in those cases where different forms of tissue with similar absorption crosssections are under investiga...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Microscopy research and technique
دوره 72 12 شماره
صفحات -
تاریخ انتشار 2009