Test beam results of a large area strip detector made on high resistivity Czochralski silicon

نویسنده

  • E. Tuominen
چکیده

We have tested the detection performance of a strip detector processed on silicon wafer grown by magnetic Czochralski (MCZ) method. This is the first time a full size Czochralski detector has been tested in a beam, although the advantages of CZ silicon have been known before. Prior to test beam measurements, the electrical characteristics of the Czochralski silicon detectors were found to be appropriate for particle detection. Using the Helsinki Silicon Beam telescope at CERN H2 test beam, the performance of the Czochralski silicon detector was shown to be comparable with the existing silicon strip detectors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Particle detectors made of high-resistivity Czochralski silicon

We have processed pin-diodes and strip detectors on nand p-type high-resistivity silicon wafers grown by magnetic Czochralski method. The Czochralski silicon (Cz-Si) wafers manufactured by Okmetic Oyj have nominal resistivity of 900O cm and 1.9 kO cm for nand p-type, respectively. The oxygen concentration in these substrates is slightly less than typically in wafers used for integrated circuit ...

متن کامل

Total Dose Dependence of Oxide Charge, Interstrip Capacitance and Breakdown Behavior of sLHC Prototype Silicon Strip Detectors and Test Structures of the SMART Collaboration

Within the R&D Program for the luminosity upgrade proposed for the Large Hadron Collider (LHC), silicon strip detectors (SSD) and test structures were manufactured on several high-resistivity substrates: ptype Magnetic Czochralski (MCz) and Float Zone (FZ), and n-type FZ. To test total dose (TID) effects they were irradiated with Co gammas and the impact of surface radiation damage on the detec...

متن کامل

Intentional thermal donor activation in magnetic Czochralski silicon

We have made a quantitative study about the thermal activation of thermal donors in high resistivity magnetic Czochralski silicon. The thermal donor activation has been performed through a thermal treatment at 430 1C up to a total time of 80min. The space charge density after each annealing step has been extracted from capacitance–voltage measurements. If the starting material is boron-doped p-...

متن کامل

The CMS Silicon Strip Tracker - Overview and Status

With an active silicon area of more than 200 m2, the silicon strip tracker of the CMS experiment, one of the experiments currently under construction for the future Large Hadron Collider at CERN, will be by far the largest silicon tracker in the world. Efficient mass production and rigid quality control are crucial to finish the detector, comprising of more than 15000 silicon strip modules, in ...

متن کامل

Radiation-hard active CMOS pixel sensors for HL-LHC detector upgrades

The luminosity of the Large Hadron Collider (LHC) will be increased during the Long Shutdown of 2022 and 2023 (LS3) in order to increase the sensitivity of its experiments. A completely new inner detector for the ATLAS experiment needs to be developed to withstand the extremely harsh environment of the upgraded, so-called High-Luminosity LHC (HL-LHC). High radiation hardness as well as granular...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003