Quantitative urine particle analysis: integrative approach for the optimal combination of automation with UF-100 and microscopic review with KOVA cell chamber.

نویسندگان

  • Cornelia Ottiger
  • Andreas R Huber
چکیده

BACKGROUND Automated systems have enabled the counting of particles in urine to be standardized. Their superiority over traditional sediment analysis has been well documented, but they have not gained wide acceptance. The reasons for this are that sediment analysis has been performed and interpreted for decades. Additionally, pathologic casts and other unknown particles still must be confirmed under the microscope. Furthermore, comparison between the methods has revealed outliers and thus decreased confidence in automation. METHODS We used the standardized KOVA cell chamber system to count particles and compared the results with UF-100 flow cytometry as an alternative to traditional sediment analysis. RESULTS We compared 252 randomly selected urine samples and obtained a review rate of 33%. Microscopic verification was necessary because of the presence of casts, yeast, sperm, dysmorphic erythrocytes, and some misclassified erythrocytes or leukocytes that were detected by incongruent dipstick results and abnormal scattergrams. We obtained correlation coefficients of 0.966 for erythrocytes and 0.935 for leukocytes. Criteria for an algorithm to identify samples that needed microscopic review were derived from comparisons between the number of particles from UF-100, dipstick results, cell chamber counting, and sediment analysis. CONCLUSIONS Automated cell counting combined with microscopic counting with a standardized cell chamber system is useful. An objective algorithm for review criteria can be developed via systematic comparison of UF-100 flow cytometry and microscopy. Only urine samples that meet these criteria need to be confirmed microscopically.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated urinalysis. Evaluation of the Sysmex UF-50.

We assessed the Sysmex UF-50 for reproducibility of results and carryover rate by performing between- and within-run precision analyses on 315 urine samples, evaluated the feasibility of using the UF-50 to measure urinary cellular and noncellular components by comparing results from the UF-50 with results of manual urinalysis using the Kova system, and performed side-by-side comparison of the w...

متن کامل

Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.

BACKGROUND Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. METHODS A total of 3...

متن کامل

Automated flow cytometry compared with an automated dipstick reader for urinalysis.

Recently, the Sysmex UF-100 flow cytometer was developed to automate urinalysis. We compared UF-100 test results with those of an automated dipstick reader. A cross-check of UF-100, dipstick, and microscopic sediment data was performed in 1001 urine samples. Good agreements (P <0.001) were obtained between UF-100 and dipstick data for erythrocytes (r = 0.636) and leukocytes (r = 0.785). Even in...

متن کامل

An evidence based care package to improve motor skills of infants living in foster care according to integrative review approach

Background: Infancy is the most important extra uterine period of brain development. And it requires environmental stimulation for expression of the developmental capabilities. Meanwhile, due to repeated environmental disparities foster care children are at risk for developmental delay. Aim: designing evidence based care package to improve motor skills of orphan living infants according to inte...

متن کامل

Dynamic Analysis and Optimal Design of FLPSS for Power Network Connected Solid Oxide Fuel Cell Using of PSO

This paper studies the theory and modeling manner of solid oxide fuel cell (SOFC) into power network and its effect on small signal stability. The paper demonstrates the fundamental module, mathematical analysis and small signal modeling of the SOFC connected to single machine infinite bus (SMIB) system. The basic contribution of the study is to attenuate the low frequency oscillations by optim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 49 4  شماره 

صفحات  -

تاریخ انتشار 2003