On the imperfect synchrony between patient and ventilator
نویسنده
چکیده
Because patient-ventilator asynchrony (PVA) is recognized as a major clinical problem for patients undergoing ventilatory assistance, automatic methods of PVA detection have been proposed in recent years. A novel approach is airflow spectral analysis, which, when related to visual inspection of airway pressure and flow waveforms, has been shown to reach a sensitivity and specificity of greater than 80% in detecting an asynchrony index of greater than 10%. The availability of automatic non-invasive methods of PVA detection at the bedside would likely be of benefit in intensive care unit practice, but they may be limited by shortcomings, so clear proof of their effectiveness is needed.
منابع مشابه
Initiation of the Neurally Adjusted Ventilatory Assist Mode in the Neonatal Period in Iran
Abstract: The new neonatal ventilation methods have been developed along with utilization of new technological tools.This device is synchronized with the patient’s respiratory efforts. The ideal synchronized breath needs to be synchronous with initiation, size, and termination of the breath without delay in detecting of initial resiratory effort by device .The synchrony of respiration contribut...
متن کاملAsynchrony and dyspnea.
Patient-ventilator synchrony and patient comfort are assumed to go hand in hand, yet few studies provide support for this common sense idea. In reality, synchrony between the patient and ventilator is complex and can be affected by the ventilator settings, type of ventilator, patient-ventilator interface, and sedation. Inspections of airway pressure and flow waveforms are reliable methods for d...
متن کاملPatient-ventilator interaction: the last 40 years.
Patient-ventilator synchrony is a complex issue affected by ventilator performance, patient characteristics, and the patient-ventilator interface. The history of patient-ventilator interaction includes avoidance of pharmacalogic paralysis, the development of spontaneous breathing systems, microprocessor technology to maximize interaction, and closed-loop control. While most clinicians agree tha...
متن کاملNeurally adjusted non-invasive ventilation in patients with chronic obstructive pulmonary disease: does patient–ventilator synchrony matter?
Patient-ventilator interaction represents an important clinical challenge during non-invasive ventilation (NIV). Doorduin and colleagues' study shows that non-invasive neurally adjusted ventilatory assist (NAVA) improves patient-ventilator interaction compared with pressure support ventilation in patients with chronic obstructive pulmonary disease. There is no doubt nowadays that NAVA is the mo...
متن کاملProportional assist ventilation and neurally adjusted ventilatory assist.
Patient-ventilator synchrony is a common problem with all patients actively triggering the mechanical ventilator. In many cases synchrony can be improved by vigilant adjustments by the managing clinician. However, in most institutions clinicians are not able to spend the time necessary to ensure synchrony in all patients. Proportional assist ventilation (PAV) and neurally adjusted ventilatory a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 15 شماره
صفحات -