Shunt Active Power Filter with Hysteresis Current Control for three Phase Ac-Dc Converter

نویسنده

  • J. N. Pandya
چکیده

This paper represents the simulation of Shunt Active Power Filter(SAPF) based on p-q theory and using hysteresis current control to obtain the gating signals for three phase ac-dc converter. The proposed active power filter is employed to reduce the current Total Harmonic Distortion (THD) drawn by the non-linear load and compensate the reactive power. The PI controller is employed to reduce the ripple voltage of the dc capacitor of the inverter. Simulation of a shunt active power filter is done in PSIM software. Simulation results have been obtained, FFT analysis of source current and load current is also presented and Total harmonic distortion of source current is calculated before and after compensation and THD of the source current after compensation is below 5% which is in permissible limit imposed by IEEE-519 standard. 1. INTRODUCTION Thyristors converters and diode rectifiers with smoothing dc capacitors are a common source of harmonic currents. The distortion of the current results from the switching operation of thyristors and its harmonic amplitude is greatly affected by the impedance of the ac side. This type of harmonic source behaves like a current source. Therefore, they are called harmonic current source. These types of loads are a matter of serious problem as they cause flicker or harmonic interference in industrial applications, transmission and distribution systems

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Scrutiny of Two Control Schemes Based on DSM and HB in Active Power Filter

This paper presents a comparative analysis between two current control strategies, constant source power and generalized Fryze current, used in Active Power Filter (APF) applications having three different modulation methods. The Hysteresis Band (HB) and first-order Delta-Sigma Modulation (DSM) as well as the second-order DSM is applied. The power section of the active power filter is viewed as...

متن کامل

Power Quality Improvement Using Fuzzy Controlled Shunt Active Filter

This paper proposes a new control method of three phase active power filterfor reducing the source current harmonics for nonlinear loads. The control strategy includes the dq transformations and hysteresis technique for current injection. Renewable energy source (solar energy) is used as a backup device for converter. Dc voltage deviations due to harmonic injections are tracked by using proport...

متن کامل

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

Comparative Power Quality Analysis of Different DSTATCOM Topologies

This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...

متن کامل

Harmonics and Reactive Power Compensation Using Shunt Hybrid Filter

The supply current is distorted by the nonlinear load such UPS, DC drives, AC drives and arc furnace. This current harmonics derates the electrical equipments. Thus the current harmonics are reduced from the supply line using Shunt Hybrid filter. The Hysteresis controller controls the active filter thus the supply current tracks the reference fundamental current extracted by the synchronous ref...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015