More on determination of ionized calcium in blood with ion-selective electrodes.
نویسنده
چکیده
444 CLINICALCHEMISTRY, Vol. 33, No. 3, 1987 used for “SuperSTAT” bedside testing, as suggested by Ng et al. (1), this temperature bias must be taken into consideration. For example, mixing a sample by rolling the container between the palms should be avoided because this also will affect the sample temperature. Finally, the influence of different control-sample temperatures on precision (e.g., quality-control plots) should be stated explicitly by the manufacturer in the product information. Making this emphasis in product documentation will be helpful because the instrument is being marketed for use by nontechnical operators.
منابع مشابه
Ionized calcium: its significance and clinical usefulness.
Maintenance of normal blood levels of ionized calcium (Ca2+) plays an important role in the management of the critically ill patient. Therefore, Ca2+ should be collected properly and measured reliably. The sound analytical performance of today's Ca2+ analyzers using ion-selective electrode technology have made measurements accurate and precise. The introduction of this technology allows rapid a...
متن کاملDetermination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore
A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...
متن کاملActivity and interference effects in measurement of ionized calcium with ion-selective electrodes.
We assessed the magnitude of the errors in ionized-calcium measurements resulting from changes in electrolyte composition for three different ion-selective electrodes: the Orion Model 93-20, the Radiometer F2112, and the Simon neutral carrier membrane electrode. We attempted to distinguish between errors arising from changes in calcium ion activity and those due to interferences in the electrod...
متن کاملA readily available source of serum for use as a precision quality-control material for ionized calcium measurement by ion-selective electrodes
A readily available source of serum ft r use as a precision quality-control material for ionized calcium measurement by ion-selective electrodes A simple method for preparing human serum for use as a precision quality-control for ionized calcium using an ion-selective electrode has been described earlier [1-1. Human citrate dextrose plasma is readily available from outdated whole blood from blo...
متن کاملLinearity and stability of the AVL and Nova magnesium and calcium ion-selective electrodes.
We studied the stability and linearity of the AVL and Nova Mg and Ca ion-selective electrodes and the relation between the ionized Ca and ionized Mg results reported by each analyzer. The response of the electrodes to different concentrations of Mg and Ca was determined for saline solutions, aqueous solutions, and serum samples. The electrodes from both manufacturers demonstrated acceptable sta...
متن کاملIon-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method
2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 33 3 شماره
صفحات -
تاریخ انتشار 1987