Coracoid Process Morphology using 3D-CT Imaging in a Malaysian Population

نویسندگان

  • II Imma
  • NM Nizlan
  • AR Ezamin
  • S Yusoff
  • MH Shukur
چکیده

Introduction: The aims of this study are to define the coracoid process anatomy in a Malaysian population, carried out on patients in Hospital Serdang with specific emphasis on the dimension of the base of coracoid process which is important in coraco-acromial (CC) ligament reconstruction, to define the average amount of bone available for use in coracoid transfer, and to compare the size of coracoid process based on gender and race, and with findings in previous studies. Materials and Methods: Fifteen pairs of computed tomography (CT) based 3-dimensional models of shoulders of patients aged between 20 to 60 years old were examined. The mean dimensions of coracoid were measured and compared with regards to gender and race. The data were also compared to previously published studies. Results: The mean length of the coracoid process was 37.94 ± 4.30 mm. Male subjects were found to have larger-sized coracoids in all dimensions as compared to female subjects. The mean tip of coracoid dimension overall was 19.99 + 1.93mm length × 10.03 + 1.48mm height × 11.63 + 2.12mm width. The mean base of coracoid dimension was 18.96 + 3.71mm length × 13.84 + 1.76mm width. No significant differences were observed with regards to racial denomination. The overall coracoid size measurements were found to be smaller compared to previous studies done on the Western population. Conclusion: This study may suggest that Malaysians have smaller coracoid dimension compared to Caucasians. The findings further suggest that the incidence of coracoid fracture and implants pull out in Malaysian subjects may be higher.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-D computed tomography reconstruction: another tool to teach anatomy in the veterinary colleges

This letter underpins the use of three-dimensional computed tomography (3D-CT) reconstruction as an aid to teach veterinary anatomy. Cases were presented to students in order to observe normal and clinically abnormal patients. The images provided excellent details of relevant structures and could serve as a tool for teaching anatomy. Many sources describe different options to enhance anatomical...

متن کامل

Anatomic Variation in Morphometry of Human Coracoid Process among Asian Population

Ethnic origin plays an important role in bone morphometry. Studies examining the influence of coracoid process have focused primarily on adults and have not included people from diverse Asian ethnic backgrounds. Our goal was to explore ethnic differences in morphometry of coracoid among Asian population. We performed morphometric measurements of coracoid process on cadaveric shoulders and shoul...

متن کامل

Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer

Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...

متن کامل

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017