Automated surveillance of 911 call data for detection of possible water contamination incidents

نویسندگان

  • Adam J Haas
  • Darcy Gibbons
  • Chrissy Dangel
  • Steve Allgeier
چکیده

BACKGROUND Drinking water contamination, with the capability to affect large populations, poses a significant risk to public health. In recent water contamination events, the impact of contamination on public health appeared in data streams monitoring health-seeking behavior. While public health surveillance has traditionally focused on the detection of pathogens, developing methods for detection of illness from fast-acting chemicals has not been an emphasis. METHODS An automated surveillance system was implemented for Cincinnati's drinking water contamination warning system to monitor health-related 911 calls in the city of Cincinnati. Incident codes indicative of possible water contamination were filtered from all 911 calls for analysis. The 911 surveillance system uses a space-time scan statistic to detect potential water contamination incidents. The frequency and characteristics of the 911 alarms over a 2.5 year period were studied. RESULTS During the evaluation, 85 alarms occurred, although most occurred prior to the implementation of an additional alerting constraint in May 2009. Data were available for analysis approximately 48 minutes after calls indicating alarms may be generated 1-2 hours after a rapid increase in call volume. Most alerts occurred in areas of high population density. The average alarm area was 9.22 square kilometers. The average number of cases in an alarm was nine calls. CONCLUSIONS The 911 surveillance system provides timely notification of possible public health events, but did have limitations. While the alarms contained incident codes and location of the caller, additional information such as medical status was not available to assist validating the cause of the alarm. Furthermore, users indicated that a better understanding of 911 system functionality is necessary to understand how it would behave in an actual water contamination event.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lessons learned from ten investigations of waterborne gastroenteritis outbreaks, France, 1998-2006.

Ten outbreaks of waterborne acute gastroenteritis (AGE) have been investigated in France since 1998. These outbreaks have affected populations of over 1,000 people, with generally high attack rates. The causal agents have been identified in six of these events. Aetiologies involved mainly noroviruses and Cryptosporidium sp. The point of entry of the contamination was located in the distribution...

متن کامل

Mining 911 Calls in New York City: Temporal Patterns, Detection, and Forecasting

The New York Police Department (NYPD) is tasked with responding to a wide range of incidents that are reported through the city’s 911 emergency hotline. Currently, response resources are distributed within police precincts on the basis of high-level summary statistics and expert reasoning. In this paper, we describe our first steps towards a better understanding of 911 call activity: temporal b...

متن کامل

Probabilistic Contaminant Source Identification in Water Distribution Infrastructure Systems

Large water distribution systems can be highly vulnerable to penetration of contaminant factors caused by different means including deliberate contamination injections. As contaminants quickly spread into a water distribution network, rapid characterization of the pollution source has a high measure of importance for early warning assessment and disaster management. In this paper, a methodology...

متن کامل

Drinking water incidents due to chemical contamination in England and Wales, 2006-2008.

Contamination of drinking water by microbiological and chemical agents can lead to adverse health effects. In England and Wales, the Chemicals Hazards and Poisons Division (CHaPD) of the Health Protection Agency provides expert advice on the consequences to public health of chemical contamination incidents affecting drinking water. In this study, we extracted data from the National Database on ...

متن کامل

Detection of children's activities in smart home based on deep learning approach

 Monitoring behavior of children in the home is the extremely important to avoid the possible injuries. Therefore, an automated monitoring system for monitoring behavior of children by researchers has been considered. The first step for designing and executing an automated monitoring system on children's behavior in closed spaces is possible with recognize their activity by the sensors in the e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2011