Early pulmonary vein reconnection as a predictor of left atrial ablation outcomes for paroxysmal atrial fibrillation.

نویسندگان

  • Michael Efremidis
  • Konstantinos Letsas
  • Georgios Giannopoulos
  • Louisa Lioni
  • Konstantinos Vlachos
  • Dimitrios Asvestas
  • Dimitrios Karlis
  • Vasileios Kareliotis
  • Hrysoula Geladari
  • Antonios Sideris
  • Spyridon Deftereos
چکیده

AIM The objective of the study was to investigate whether early pulmonary vein reconnection (PVR) is a predictor of late arrhythmia recurrence after a single ablation procedure for paroxysmal atrial fibrillation (AF). Further ablation was delivered to patients with acute PVR to test whether this strategy could reduce recurrences. METHODS AND RESULTS One hundred and forty-four consecutive patients with symptomatic, drug-refractory paroxysmal AF, undergoing pulmonary vein isolation (PVI), were assigned to the 'PVR30 test' group, where PVR was monitored for 30 min after initial PVI and further ablation was applied if needed, and compared with a control group of 128 patients, where the procedure was terminated after initial successful isolation. During a mean follow-up of 17.7 months, sinus rhythm was maintained in 101 patients in the 'PVR30 test' group (70.1%) vs. 78 in the control group (60.9%) (P = 0.13). Among patients with acute PVR and reablation after 30 min, the recurrence rate was 45.3 vs. 39.1% in the control group (P = 0.47). Multivariable logistic regression analysis showed that PVR was independently associated with AF recurrence (adjusted hazard ratio 4.7, 95% confidence interval 1.8-12.2), along with left atrial diameter (adjusted hazard ratio 1.3/mm of higher diameter, 95% confidence interval 1.2-1.4). CONCLUSION In patients with paroxysmal AF undergoing a single ablation procedure, PVR 30 min after the initial PVI is associated with late AF recurrence. However, the strategy of 30 min waiting and reablating does not appear to be superior to immediate termination of the procedure after initial PVI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Should Adenosine Test be Performed Systematically at the End of Atrial Fibrillation Ablation Procedure?

Pulmonary vein (PV) reconnection is a major limitation of atrial fibrillation (AF) ablation and is a significant contributor for arrhythmia recurrence, particularly in patients with paroxysmal AF. Recent technological advances, including the use of steerable sheaths and force sensing catheters resulted in reduced incidence of PV reconnection; however its incidence remains unacceptably high. Add...

متن کامل

Early Pulmonary Vein Conduction Recovery after Catheter Ablation of Atrial Fibrillation.

Background Pulmonary vein electrical isolation (PVI) is an effective treatment for atrial fibrillation (AF). However, recurrence of pulmonary vein (PV) conduction after ablation may limit long-term success. Early identification and treatment of acute PV conduction recovery during initial ablation may have an impact on subsequent clinical results. Objective To assess the prevalence of acute PV...

متن کامل

Challenges and Outcomes of Posterior Wall Isolation for Ablation of Atrial Fibrillation

BACKGROUND The left atrial posterior wall (PW) often contains sites required for maintenance of atrial fibrillation (AF). Electrical isolation of the PW is an important feature of all open surgeries for AF. This study assessed the ability of current ablation techniques to achieve PW isolation (PWI) and its effect on recurrent AF. METHODS AND RESULTS Fifty-seven consecutive patients with persi...

متن کامل

Clinical implication of adenosine test at repeat atrial fibrillation ablation procedure: the importance of detecting dormant thoracic vein conduction.

BACKGROUND Pulmonary vein reconnection after electrical isolation is commonly observed in the context of atrial fibrillation ablation and is associated with recurrent atrial tachyarrhythmias. Adenosine test was been performed to identify acute dormant conduction immediately after pulmonary vein isolation at index procedure. However, the utility of adenosine test at repeat procedure has not been...

متن کامل

Spatial distribution of electrical reconnection after pulmonary vein isolation in patients with recurrent paroxysmal atrial fibrillation

INTRODUCTION Recurrence of atrial fibrillation after pulmonary vein isolation (PVI) occurs frequently and may be associated with electrical reconnection of the pulmonary veins (PV). We investigated spatial distribution of electrical reconnection during re-do procedures in patients with paroxysmal atrial fibrillation who had previous successful acute electrical PVI with either single irrigated t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 17 5  شماره 

صفحات  -

تاریخ انتشار 2015