Comment on "Calculated absorbed-dose ratios, TG51/TG21, for most widely used cylindrical and parallel-plate ion chambers over a range of photon and electron energies".

نویسنده

  • M Saiful Huq
چکیده

Task Group 51 (TG51), of the Radiation Therapy Committee of the American Association of Physicists in Medicine (AAPM), has developed a calibration protocol for high-energy photon and electron therapy beams based on absorbed dose standards. This protocol is intended to replace the air-kerma based protocol developed by an earlier AAPM task group (TG21). Conversion to the newer protocol introduces a change in the determined absorbed dose. In this work, the change in dose is expressed as the ratio of the doses (TG51/TG21) based on the two protocols. Dose is compared at the TG-51 reference depths of 10 cm for photons and d(ref) for electrons. Dose ratios are presented for a variety of ion chambers over a range of photon and electron energies. The TG51/TG21 dose ratios presented here are based on the dosimetry factors provided by the two protocols and the chamber-specific absorbed dose and exposure calibration factors (N60Co(D,w) and Nx) provided by the Accredited Dosimetry Calibration Laboratory (ADCL) at The University of Texas, M. D. Anderson Cancer Center (MDACC). As such, the values presented here represent the expected discrepancies between the two protocols due only to changes in the dosimetry parameters and the differences in chamber-specific dose and air-kerma standards. These values are independent of factors such as measurement uncertainties, setup errors, and inconsistencies arising from the mix of different phantoms and ion chambers for the two protocols. Therefore, these ratios may serve as a guide for institutions performing measurements for the switch from TG21-to-TG51 based calibration. Any significant deviation in the ratio obtained from measurements versus those presented here should prompt a review to identify possible errors and inconsistencies. For all cylindrical chambers included here, the TG51/TG21 dose ratios are the same within +/-0.6%, irrespective of the make and model of the chamber, for each photon and electron beam included. Photon beams show the TG51/TG21 dose ratios decreasing with energy, whereas electrons exhibit the opposite trend. The dose ratio for photons is near 1.00 at 18 mV increasing to near 1.01 at 4 mV while the dose ratio for electrons is near 1.02 at 20 MeV decreasing only 0.5% to near 1.015 at 6 MeV. For parallel-plate chambers, the situation is complicated by the two possible methods of obtaining calibration factors: through an ADCL or through a cross-comparison with a cylindrical chamber in a high-energy electron beam. For some chambers, the two methods lead to significantly different calibration factors, which in turn lead to significantly different TG51/TG21 results for the same chamber. Data show that if both N60Co(D,w) and Nx are obtained from the same source, namely an ADCL or a cross comparison, the TG51/TG21 results for parallel-plate chambers are similar to those for cylindrical chambers. However, an inconsistent set of calibration factors, i.e., using N60Co(D,w) x k(ecal) from an ADCL but Ngas from a cross comparison or vice versa, can introduce an additional uncertainty up to 2.5% in the TG51/TG21 dose ratios.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective Point of Measurement in Cylindrical Ion Chamber for Megavoltage Photon Beams

Introduction For dose measurement in Megavoltage (MV) photon beams with ion chambers, the effect of volume occupied by the air cavity is not negligible. Therefore, the result of measurement should be corrected with a displacement perturbation correction factor (Pdis) or using an effective point of measurement (EPOM). The aim of this study is to calculate the EPOM for cylindrical ion chamber and...

متن کامل

Some steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department

Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...

متن کامل

Monte Carlo calculations of beam quality correction factors

Current dosimetry protocols (AAPM, IAEA, DIN) recommend the use of parallel-plate ionization chambers for the measurement of absorbed dose-towater in clinical electron beams. For well-guarded plane-parallel chambers, it is assumed that the perturbation correction pQ is unity for all electron energies. In this study, we present detailed Monte Carlo simulations with the EGSnrc code for the widely...

متن کامل

Monte Carlo calculations of beam quality correction factors kQ for electron dosimetry with a parallel-plate Roos chamber.

Current dosimetry protocols (AAPM, IAEA, DIN) recommend the use of parallel-plate ionization chambers for the measurement of absorbed dose-to-water in clinical electron beams. For well-guarded plane-parallel chambers, it is assumed that the perturbation correction pQ is unity for all electron energies. In this study, we present detailed Monte Carlo simulations with the EGSnrc code for the widel...

متن کامل

Monte Carlo calculations of electron beam quality conversion factors for several ion chamber types.

PURPOSE To provide a comprehensive investigation of electron beam reference dosimetry using Monte Carlo simulations of the response of 10 plane-parallel and 18 cylindrical ion chamber types. Specific emphasis is placed on the determination of the optimal shift of the chambers' effective point of measurement (EPOM) and beam quality conversion factors. METHODS The EGSnrc system is used for calc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 29 7  شماره 

صفحات  -

تاریخ انتشار 2002