Comparison between two iodine-125 brachytherapy implant techniques: pre-planning and intra-operative by various dosimetry quality indicators.

نویسندگان

  • Haim Matzkin
  • Issac Kaver
  • Letizia Bramante-Schreiber
  • Ruben Agai
  • Ofer Merimsky
  • Moshe Inbar
چکیده

PURPOSE To prospectively compare two widely used seed implant techniques: pre-planning and intra-operative planning, based on 1 month post-implant CT-based evaluation. METHODS We report results of a detailed 1 month post-operative dosimetric evaluation and comparison between 142 consecutive men with prostate adenocarcinoma treated by the pre-planning methodology and 214 men treated with the real-time, intra-operative seed implant method. RESULTS Baseline parameters patient's age, Gleason score, clinical stage, and gland volume were similar in both groups (p>0.05). Length of physicist time and operating room team time were more than double in the pre-planned group compared to the intra-operative one (205 vs 100 min). Based on day 30 post-implant CT, for patients treated with the pre-planning method, mean V90, V100 and V150 (percent prostate volume receiving 90, 100 and 150% of the prescribed dose) were 67.5, 58.35 and 21.5%, respectively, while for the intra-operative group they were 97.9, 95.2 and 45%, respectively (p<0.01). Mean D90, expressed as percent of target matched peripheral dose (minimal dose covering 90% of the gland volume) was 53% for the pre-planned group and 114% for the intra-operative group of men (p<0.01). Short-term morbidity was minimal in both groups and did not correlate with the technique employed. CONCLUSIONS This large-scale comparison of implant adequacy favours real-time intra-operative method. While all dosimetric parameters are significantly better with this method, no increased early morbidity was noted. Longer-term PSA-based clinical outcome should substantiate our contention of the superiority of the intra-operative method when compared to the pre-planning one.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iodine-125 brachytherapy for localized prostate cancer and urinary morbidity: a prospective comparison of two seed implant methods-preplanning and intraoperative planning.

OBJECTIVES To compare morbidity between two currently used iodine-125 seed implantation techniques for the treatment of localized prostate cancer. METHODS Iodine-125 brachytherapy was used in 300 consecutive men with localized prostate cancer. Two seed implant techniques were used: preplanning, using preloaded needles, and intraoperative planning, using a Mick applicator. A comparison was mad...

متن کامل

Quantifying Iodine-125 Placement Accuracy In Prostate Brachytherapy Using Post-Implant Transrectal Ultrasound Images

PURPOSE: The quality of a prostate brachytherapy implant depends on the accurate placement of sources. This study quantifies the misplacement of iodine-125 sources from the intended location using intra-operative ultrasound images. METHOD AND MATERIALS Iodine-125 sources were manually identified in the post-implant ultrasound images and compared to the pre-operative plan. Due to the subjective ...

متن کامل

Prospective multi-center dosimetry study of low-dose Iodine-125 prostate brachytherapy performed after transurethral resection

PURPOSE To evaluate in a multicenter setting the ability of centers to perform pre-implant permanent prostate brachytherapy planning, fulfilling dosimetric goals and constraints based on the Groupe de Curiethérapie-European Society for Radiotherapy and Oncology guidelines in the setting of implantation after prior prostate transurethral resection (TURP). MATERIAL AND METHODS A reference trans...

متن کامل

Assessment of I-125 seed implant accuracy when using the live-planning technique for low dose rate prostate brachytherapy

BACKGROUND Low risk prostate cancers are commonly treated with low dose rate (LDR) brachytherapy involving I-125 seeds. The implementation of a 'live-planning' technique at the Royal Adelaide Hospital (RAH) in 2007 enabled the completion of the whole procedure (i.e. scanning, planning and implant) in one sitting. 'Live-planning' has the advantage of a more reliable delivery of the planned treat...

متن کامل

Conformal prostate brachytherapy guided by realtime dynamic dose calculations using permanent 125iodine implants: technical description and preliminary experience.

OBJECTIVE Low dose rate (LDR) prostate brachytherapy (permanent 125I or 103Pd seeds) is an accepted treatment option for low risk prostate cancer patients. However, differences in prostate spatial location, volume and gland deformation between the images obtained during pre-planning and later on during the implant procedure prevent the pre-planned intended dose to be accurately delivered. We ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

دوره 68 3  شماره 

صفحات  -

تاریخ انتشار 2003