A search for novel thermoluminescent radiation dosimeter media.

نویسندگان

  • Khalid H Al-Hinai
  • Nadjima Benkara Mohd
  • Nurul Rozullyah Zulkepely
  • Roslan Md Nor
  • Yusoff Mohd Amin
  • D A Bradley
چکیده

We describe two example pilot efforts to help define new thermoluminescent dosimeter media. The first concerns ZnS:Mn nanophosphors, prepared by chemical precipitation using zinc and sodium sulfate, doped with manganese sulfate at concentrations varying from 1 to 3mol. The second concerns chemical vapor deposited diamond, produced as a thin film or as amorphous carbon on a single-crystal silicon substrate, each deposited under the same conditions, use being made of the hot filament-chemical vapor deposition (HFCVD) technique. The gas concentrations used were 1% CH4 in 99% H2 and 25% CH4 in 75% H2. Characterization of formations used FESEM, XRD and EDX. The nanophosphors consisted of particles of sizes in the range 85-150nm, the thermoluminescence (TL)-based radiation detection medium giving rise to a single peaked glow curve of maximum yield at a temperature of 250°C at a heating rate of 5°C/s. The TL response increased linearly with radiation dose, ZnS doped to 2mol of Mn being found the most sensitive. Regarding chemical vapor deposited (CVD) carbon, inappreciable TL was found for the resultant ball-like amorphous carbon films, graphite, and the silicon substrate, whereas CVD diamond films showed a promising degree of linearity with dose. For both the ZnS and diamond samples, TL signal fading was appreciable, being some 40% per day for ZnS and>50% per day for CVD films even under storage in the dark at room temperature, making it apparent that there is need to adjust parameters such as the size of nanoparticles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sintered Al2O3 based Materials for Radiotherapy Thermoluminescent Dosimeter Applications

INTRODUCTION The thermoluminescent (TL) properties of various materials have been studied since a long time but many of these developments never reach the thermoluminescent dosimeter (TLD) users. α-Al2O3:C TL detectors were first developed and produced at Urals Polytechnical Institute ( UPI ) (1) in the form of a single crystal. These TLD ( model 2600 – 80 ) are now supplied by Victoreen to man...

متن کامل

Office of Radiation Protection BACKGROUND RADIATION ACCUMULATION AND LOWER LIMIT OF USED BY THE CENTRALIZED EXTERNAL DOSIMETRY SYSTEM DETECTION IN THERMOLUMINESCENT BETA-GAMMA DOSIMETERS

A value for "average background radiation" of 0.75 mR/week has been determined from a total of 1680 thermoluminescent dosimeters (TLD's) exposed in 70 houses for periods up to one year. The distribution of results indicates a rather large variation among houses, with a few locations exhibiting backgrounds double the general average. Some discrepancies in the short-term background accumulation o...

متن کامل

An Analysis of Radiation Field Characteristics for Extremity Dosimetry in Nuclear Power Plants

Workers who maintain the water chambers of steam generators during the maintenance period in Nuclear Power Plants (NPPs) have a higher likelihood of high radiation exposure even if they were exposed for a short period of time. In particular, it is expected that the hands would receive the highest radiation exposure because of its contact with radiation materials. In this study, characteristic a...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

Fiber-optic-coupled, laser heated thermoluminescence dosimeter for remote radiation sensing

We describe an optically transparent, laser heated, thermoluminescent glass dosimeter that is used for fiber-optic-coupled remote radiation monitoring. The glass consists of ZnS nanocrystallites embedded in a Vycor glass host, doped with Cu and Nd ions. An 807 nm, 1 W GaAlAs laser is used to rapidly heat microscopic regions, surrounding the Nd ions, in the composite glass to stimulate blue-gree...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2013