Volume calculation of CT lung lesions based on Halton low-discrepancy sequences

نویسندگان

  • Shusheng Li
  • Liansheng Wang
  • Shuo Li
چکیده

Volume calculation from the Computed Tomography (CT) lung lesions data is a significant parameter for clinical diagnosis. The volume is widely used to assess the severity of the lung nodules and track its progression, however, the accuracy and efficiency of previous studies are not well achieved for clinical uses. It remains to be a challenging task due to its tight attachment to the lung wall, inhomogeneous background noises and large variations in sizes and shape. In this paper, we employ Halton low-discrepancy sequences to calculate the volume of the lung lesions. The proposed method directly compute the volume without the procedure of three-dimension (3D) model reconstruction and surface triangulation, which significantly improves the efficiency and reduces the complexity. The main steps of the proposed method are: (1) generate a certain number of random points in each slice using Halton lowdiscrepancy sequences and calculate the lesion area of each slice through the proportion; (2) obtain the volume by integrating the areas in the sagittal direction. In order to evaluate our proposed method, the experiments were conducted on the sufficient data sets with different size of lung lesions. With the uniform distribution of random points, our proposed method achieves more accurate results compared with other methods, which demonstrates the robustness and accuracy for the volume calculation of CT lung lesions. In addition, our proposed method is easy to follow and can be extensively applied to other applications, e.g., volume calculation of liver tumor, atrial wall aneurysm, etc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

On Atanassov's methods for discrepancy bounds of low-discrepancy sequences

The aim of this survey paper is to give an updated overview of results on low discrepancy sequences obtained via Atanassov’s methods. These methods first initiated for Halton sequences have been later on extended to generalizations of these sequences and to (t, s)sequences, the other well known family of low discrepancy sequences, including polynomial arithmetic analogues of Halton sequences.

متن کامل

Halton-type sequences in rational bases in the ring of rational integers and in the ring of polynomials over a finite field

The aim of this paper is to generalize the well-known Halton sequences from integer bases to rational number bases and to translate this concept of Halton-type sequences to rational bases from the ring of integers to the ring of polynomials over a finite field. These two new classes of Haltontype sequences are low-discrepancy sequences. More exactly, the first class, based on the ring of intege...

متن کامل

Randomized Halton Sequences

The Halton sequence is a well-known multi-dimensional low discrepancy sequence. In this paper, we propose a new method for randomizing the Halton sequence: we randomize the start point of each component of the sequence. This method combines the potential accuracy advantage of Halton sequence in multi-dimensional integration with the practical error estimation advantage of Monte Carlo methods. T...

متن کامل

Random and Deterministic Digit Permutations of the Halton Sequence*

The Halton sequence is one of the classical low-discrepancy sequences. It is effectively used in numerical integration when the dimension is small, however, for larger dimensions, the uniformity of the sequence quickly degrades. As a remedy, generalized (scrambled) Halton sequences have been introduced by several researchers since the 1970s. In a generalized Halton sequence, the digits of the o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017