Transcatheter Closures for Fistula Tract and Paravalvular Leak after Mitral Valve Replacement and Tricuspid Annuloplasty

نویسندگان

  • Sang Yong Om
  • Gyung Min Park
  • Jin Yong Kim
  • Yong Hoon Yoon
  • Sinwon Lee
  • Young-Hak Kim
  • Jae-Kwan Song
چکیده

Paravalvular leaks (PVLs) often occur after surgical valve replacement. Surgical reoperation has been the gold standard of therapy for PVLs, but it carries a higher operative risk and an increased incidence of re-leaks compared to the initial surgery. In high surgical risk patients with appropriate geometries, transcatheter closure of PVLs could be an alternative to redo-surgery. Here, we report a case of successful staged transcatheter closures of a fistula tract between the aorta and right atrium, and mitral PVLs after mitral valve replacement and tricuspid annuloplasty.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous transcatheter closure of prosthetic mitral paravalvular leaks: are we there yet?

A potential complication of mitral valve replacement surgery is the development of a paravalvular leak (PVL). Percutaneous transcatheter closures of PVLs using a wide array of devices have been reported in the literature, although the procedural success rate of this approach remains variable. One major challenge of transcatheter mitral PVL closure lies in the ability to adequately visualize the...

متن کامل

Minimally invasive off-pump valve-in-a-ring implantation: the atrial transcatheter approach for re-operative mitral valve replacement after failed repair.

OBJECTIVE Based upon recent developments in transcatheter technology, this study was designed to evaluate the feasibility and haemodynamic performance of transcatheter valve-in-a-ring (VinR) implantation for potentially failed mitral repair using a minimally invasive, transatrial, off-pump approach. METHODS Adult sheep (54.3+/-3.0 kg) underwent mitral valve repair with a 26 mm complete annulo...

متن کامل

Multiparametric Assessment of Post-Transcatheter Aortic Valve Replacement Paravalvular Regurgitation Grading by Transthoracic Echocardiography and Cardiac Magnetic Resonance

Purpose: Paravalvular regurgitation post-transcatheter valve replacement is associated with poor outcomes. The Valve Academic Research Consortium has defined qualitative and quantitative criteria for assessing paravalvular leak severity by transthoracic echocardiography. Cardiac magnetic resonance imaging is highly accurate and reproducible in measuring aortic flow volumes, and has been used fo...

متن کامل

Percutaneous closure of paravalvular leak after transcatheter aortic valve replacement.

An 86-year-old male underwent TAVR with a 26 mm Sapien valve, co valve, moderate-to-severe paravalvular AI persisted. The patient quick catheter was advanced across the tract over a stiff angled glidewire; a reduction of AI and rapid clinical recovery. (A) TEE long-axis and (B) shor confirms the 4-F MP catheter has been advanced outside the struts of th resulting in substantial reduction of AI ...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 44  شماره 

صفحات  -

تاریخ انتشار 2014