Different clinical outcome of paravalvular leakage after aortic or mitral valve replacement.

نویسندگان

  • In Jeong Cho
  • Jeonggeun Moon
  • Chi Young Shim
  • Yangsoo Jang
  • Namsik Chung
  • Byung-Chul Chang
  • Jong-Won Ha
چکیده

Although aortic valve replacement (AVR) and mitral valve replacement (MVR) are the most commonly performed prosthetic valve replacement operations, it is unclear whether clinical outcomes of paravalvular leakage (PVL) after MVR or AVR are different. It was hypothesized that clinical outcomes of PVL after AVR would be more favorable than after MVR because the pressure gradient is much larger in PVL occurring at the mitral position, which happens at the systolic phase, than at the aortic valve. Over a 12-year period, 82 patients with PVL were identified. After excluding patients who required immediate surgical repair for severe symptoms, patients with Behçet disease or infective endocarditis, and those with PVL involving both valves, 54 remaining patients (21 women, mean age 56 ± 14 years, 23 AVRs) with mild to moderate leakage constituted the study population. The end points were cardiac death, all-cause mortality, repeat surgery, and urgent admission for heart failure. During a median follow-up period of 35 months, there were 27 events, including 23 repeated surgeries, 2 cardiac deaths, 1 noncardiac death, and 1 admission for heart failure. Cox regression analysis revealed that the valve location of PVL was the only independent clinical predictor of event-free survival. The estimated 8-year event-free survival rate was significantly higher in patients with PVL after AVR than those after MVR (70 ± 12% vs 16 ± 8%, p <0.0001). In conclusion, PVL after AVR demonstrated more favorable long-term clinical outcomes compared to that after MVR. In patients who develop PVL after AVR, repeat surgery may be deferred. However, in patients with PVL after MVR, more aggressive therapeutic approaches should be considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Mitral Paravalvular Leakage After Mitral Valve Replacement Using Cardiac Computed Tomography

Paravalvular leakage (PVL) is uncommon but potentially serious complication after valve replacement, which occurs 7% to 17% after mitral valve replacement (MVR) and 2% to 10% after aortic valve replacement. Although most PVLs are asymptomatic and have a benign clinical course, an estimated 1% to 5% of patients with PVLs show serious clinical consequences, with especially more undesirable outcom...

متن کامل

Comparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery

Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Mechanical Hemolysis after Mitral Valve Repair: Report of a Case

A 60-year-old man underwent aortic valve replacement with a bileaflet mechanical valve for aortic regurgitation and mitral valve repair using a prosthetic ring for mitral regurgitation (MR). Intraoperative transesophageal echocardiography (TEE) confirmed no residual MR and a normally functioning aortic prosthetic valve without a paravalvular leak. One week after the operation, transthoracic ech...

متن کامل

Valve dysfunction of the cloth-covered Starr-Edwards ball valve.

BACKGROUND Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were used for valve replacement on a routine basis. METHODS AND RESULTS Among the 66 operative survivors who underwent an isolated aortic or mitral valve replacement, 20 patients required reoperation 22 times because of valve dysfunction, thromboembolic complication, paravalvular leakage, hemolytic anemia, an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of cardiology

دوره 107 2  شماره 

صفحات  -

تاریخ انتشار 2011