Comparison of myocardial perfusion imaging between the new high-speed gamma camera and the standard anger camera.

نویسندگان

  • Hirokazu Tanaka
  • Taishiro Chikamori
  • Satoshi Hida
  • Kenji Uchida
  • Yuko Igarashi
  • Tsuyoshi Yokoyama
  • Masaki Takahashi
  • Chie Shiba
  • Mana Yoshimura
  • Koichi Tokuuye
  • Akira Yamashina
چکیده

BACKGROUND Cadmium-zinc-telluride (CZT) solid-state detectors have been recently introduced into the field of myocardial perfusion imaging. The aim of this study was to prospectively compare the diagnostic performance of the CZT high-speed gamma camera (Discovery NM 530c) with that of the standard 3-head gamma camera in the same group of patients. METHODS AND RESULTS The study group consisted of 150 consecutive patients who underwent a 1-day stress-rest (99m)Tc-sestamibi or tetrofosmin imaging protocol. Image acquisition was performed first on a standard gamma camera with a 15-min scan time each for stress and for rest. All scans were immediately repeated on a CZT camera with a 5-min scan time for stress and a 3-min scan time for rest, using list mode. The correlations between the CZT camera and the standard camera for perfusion and function analyses were strong within narrow Bland-Altman limits of agreement. Using list mode analysis, image quality for stress was rated as good or excellent in 97% of the 3-min scans, and in 100% of the ≥4-min scans. For CZT scans at rest, similarly, image quality was rated as good or excellent in 94% of the 1-min scans, and in 100% of the ≥2-min scans. CONCLUSIONS The novel CZT camera provides excellent image quality, which is equivalent to standard myocardial single-photon emission computed tomography, despite a short scan time of less than half of the standard time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New toys for nuclear cardiologists.

Gordon Liljestrand is credited with establishing modern nuclear cardiology as a noninvasive imaging modality in 1939.1 Table summarizes major technological advancements in myocardial perfusion imaging over the past 70 years that have led to more accurate assessment of coronary artery disease (CAD). Most of these technical advances have involved radioisotopes and computer software. Camera hardwa...

متن کامل

Determination of Uterus Absorbed Dose by Patients following Myocardial Perfusion Scan using TLD and Conjugate View Methods

Introduction: The determination of patient’s absorbed dose is the first step of radiation protection which depends on the quantification of organ activity in nuclear medicine. The aim of the present study was to determine the absorbed dose by patient’s uterus following myocardial perfusion scan with 99mTC-sestamibi using Theroluminescnce dosimetry (TLD) and conjugate-view metho...

متن کامل

Comparative assessment of the accuracy of maximum likelihood and correlated signal enhancement algorithm positioning methods in gamma camera with large square photomultiplier tubes

Introduction: The gamma cameras, based on scintillation crystal followed by an array of photomultiplier tubes (PMTs), play a crucial role in nuclear medicine. The use of square PMTs provides the minimum dead zones in the camera. The camera with square PMTs also reduces the number of PMTs relative to the detection area. Introduction of a positioning algorithm to improve the spat...

متن کامل

Amorphous Silicon Flat Panel Imagers for Medical Application

A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...

متن کامل

The truncation artifact in a skinny patient following myocardial perfusion SPECT

Myocardial perfusion SPECT is one of the most common imaging techniques performed in nuclear medicine departments. To avoid misleading interpretation, it is necessary to address the quality control and technical problems. The truncation artifact occurs when the patient size is large relative to the field of view of the camera, causing false perfusion defects in the LV myocardium, misinterpreted...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 77 4  شماره 

صفحات  -

تاریخ انتشار 2013