Reactive hyperemia in the human finger.

نویسندگان

  • A C BURTON
  • D J PATEL
چکیده

Reactive hyporcmia in the finger was investigated in 16 experiments on 5 normal subjects, using venous occlusion plethysmography. Since the flow is so variable from moment to moment, the simultaneous "corrected" flow in a control finger, not occluded, was subtracted from tho flow in the test finger, so the difference gave the effect of occlusion free from fluctuations of central origin. The absolute amount and the duration of extra blood flow increased with the (jeriod of occlusion. The percentage of the calculated "blood flow debt" repaid was variable, with a mean of 51 per cent ± 36. S.D. (CTM ± 6 per cent). This is greatly in excess of nutritional debt of the skin.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Younger age is associated with lower reactive hyperemic index but not lower flow-mediated dilation among children and adolescents.

BACKGROUND The use of digital reactive hyperemia as a measure of endothelial function among children and adolescents is becoming increasingly common. However, unexpected observations of low reactive hyperemic index values in younger children in our laboratory led us to conduct a study evaluating the influence of age, sex, height, weight, blood pressure, body mass index (BMI), and finger volume ...

متن کامل

Diminished finger volume pulse in borderline hypertension: evidence for early structural vascular abnormality.

Digital volume pulse maximum dilation was determined in 27 patients with borderline essential hypertension (BHT) and 28 age-matched normotensive controls (NT). Finger pulse volume (PV) and finger systolic pressure (SBP) were measured by pneumoplethysmography during vasodilation induced by combining direct and reflex heat dilation and reactive hyperemia. Finger SBP was higher (p less than 0.01) ...

متن کامل

Assessment of skin blood content and oxygenation in spinal cord injured subjects during reactive hyperemia.

This study was undertaken to determine whether the reactive hyperemia response following ischemia in spinal cord injured (SCI) individuals is different from that which occurs in able-bodied (AB) individuals. The reactive hyperemia response was produced by applying a pressure of 150 mmHg for 300 s, 600 s, and 900 s to the skin over the greater trochanter in 10 SCI and 10 AB subjects using a comp...

متن کامل

A Novel Practical to Demonstrate Systemic and Local Regulation of Circulation in A Human Subject

Purpose of the study: Systemic and local regulation of peripheral circulation is a vital concept to be taught to undergraduate medical students. There is lack of an effective practical module to demonstrate and reinforce the theoretical understanding of this concept. Methodology: We designed a simple feasible novel practical using finger pulse recording coupled with hand grip test and reactive ...

متن کامل

Sensitivity of digital thermal monitoring parameters to reactive hyperemia.

Both structural and functional evaluations of the endothelium exist in order to diagnose cardiovascular disease (CVD) in its asymptomatic stages. Vascular reactivity, a functional evaluation of the endothelium in response to factors such as occlusion, cold, and stress, in addition to plasma markers, is the most widely accepted test and has been found to be a better predictor of the health of th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 4 6  شماره 

صفحات  -

تاریخ انتشار 1956