Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure.

نویسندگان

  • Arun D Nagdev
  • Roland C Merchant
  • Alfredo Tirado-Gonzalez
  • Craig A Sisson
  • Michael C Murphy
چکیده

STUDY OBJECTIVE Among adult emergency department (ED) patients undergoing central venous catheterization, we determine whether a greater than or equal to 50% decrease in inferior vena cava diameter is associated with a central venous pressure of less than 8 mm Hg. METHODS Adult patients undergoing central venous catheterization were enrolled in a prospective, observational study. Inferior vena cava inspiratory and expiratory diameters were measured by 2-dimensional bedside ultrasonography. The caval index was calculated as the relative decrease in inferior vena cava diameter during 1 respiratory cycle. The correlation of central venous pressure and caval index was calculated. The sensitivity, specificity, and positive and negative predictive values of a caval index greater than or equal to 50% that was associated with a central venous pressure less than 8 mm Hg were estimated. RESULTS Of 73 patients, the median age was 63 years and 60% were women. Mean time and fluid administered from ultrasonographic measurement to central venous pressure determination were 6.5 minutes and 45 mL, respectively. Of the 73 participants, 32% had a central venous pressure less than 8 mm Hg. The correlation between caval index and central venous pressure was -0.74 (95% confidence interval [CI] -0.82 to -0.63). The sensitivity of caval index greater than or equal to 50% to predict a central venous pressure less than 8 mm Hg was 91% (95% CI 71% to 99%), the specificity was 94% (95% CI 84% to 99%), the positive predictive value was 87% (95% CI 66% to 97%), and the negative predictive value was 96% (95% CI 86% to 99%). CONCLUSION Bedside ultrasonographic measurement of caval index greater than or equal to 50% is strongly associated with a low central venous pressure. Bedside measurements of caval index could be a useful noninvasive tool to determine central venous pressure during the initial evaluation of the ED patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی ارزش تشخیصی میزانCaval index در تعیین فشار ورید مرکزی پایین در مقایسه با روش تهاجمی در بیماران بستری در ICU بیمارستان شهید باهنر کرمان

Introduction: Measurement of central venous pressure can be regarded as a beneficial guide in order to assess a patient's hemodynamic status, specifically in patient with sever sepsis and septic shock, for whom a central venous pressure of less than 8mmhg is considered as an indicator for aggressive intravenous fluid replacement. Therefore, this study aimed to investigate the ultrasonographic e...

متن کامل

Correlation of Ultrasonographic Measurement of Inferior Vena Cava Collapsibility Index with Central Venous Pressure in Diagnosis and Management of Neonatal Shock

Background: Neonatal intensive care unit (NICU)Conventionally, Central Venous Pressure (CVP) monitoring has beenused by intensivists to measure intravascular volume. However, it is an invasive procedure resulting in many complications. Non-invasive ultrasonographic measurement of inferior vena cava collapsibility index (IVC-CI) is a promising alternative. Therefore, this study wasconducte...

متن کامل

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

Measurement of Central Venous Pressure Using Ultrasound in Emergency Department

BACKGROUND In order to assessment of intravascular fluid measurement of central venous pressure (CVP) is used via central venous catheterization (CVC). This procedure is highly invasive and may cause serious complications such as pneumothorax, infection, hematoma and etc. It is so valuable procedure if we can uses a less invasive or noninvasive procedure to assess patients intravascular fluid i...

متن کامل

Internal Jugular Vein Height and Inferior Vena Cava Diameter Measurement using Ultrasound to Determine Central Venous Pressure: A Correlation Study.

OBJECTIVE To determine the correlation between central venous pressure (CVP) measured by conventional central venous access and ultrasonographic measurement of internal jugular vein (IJV) height and inferior vena cava (IVC) diameter. METHODS A prospective, cross-sectional, convenience sampling observational study. RESULTS 25 patients from the Emergency Department (ED) Universiti Kebangsaan ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of emergency medicine

دوره 55 3  شماره 

صفحات  -

تاریخ انتشار 2010