Effect of a combination of torsional and cyclic fatigue preloading on the fracture behavior of K3 and K3XF instruments.

نویسندگان

  • Ya Shen
  • Abdullah Mahmoud Riyahi
  • Les Campbell
  • Huimin Zhou
  • Tianfeng Du
  • Zhejun Wang
  • Wei Qian
  • Markus Haapasalo
چکیده

INTRODUCTION The purpose of this study was to evaluate the effect of various degrees of cyclic fatigue on torsional failure and torsional preloading on the cyclic fatigue life of heat-treated K3XF nickel-titanium (NiTi) instruments (SybronEndo, Orange, CA). METHODS The mean number of cycles until failure (Nf) of K3XF and K3 NiTi instruments was examined in a 3-point bending apparatus with a 7-mm radius and 45° curve. Torque and distortion angles at failure of new instruments and instruments stressed to 25%, 50%, and 75% of the Nf were measured according to ISO 3630-1. Other new files were preloaded at 25%, 50%, and 75% of the mean distortion angles before the fatigue test. After torsional preloading, the Nf was examined. The fracture surface of each fragment was examined with a scanning electron microscope. RESULTS The fatigue resistance of K3XF instruments was 2 times higher than that of K3 instruments (P < .05). The torque and angle of rotation at fracture of K3XF instruments were similar to those of K3 instruments. The 25%, 50%, and 75% torsional preloading significantly lowered the Nf of both K3 and K3XF instruments (P < .05). In the fatigue prestressed groups, K3 instruments with 75% preloading had significantly lower torque and distortion angles than unused K3 instruments (P < .05). The fractographic patterns corresponded to the pattern defined by the last stage test. CONCLUSIONS A low amount of torsional preloading reduced the fatigue resistance of K3 and K3XF instruments. A high amount of precycling fatigue significantly reduced the torsional resistance of K3 instruments. The torsional resistance of K3XF instruments was less affected by previous load cycling even after extensive precycling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fracture Resistance of K3 Nickel-Titanium Files Made from Different Thermal Treatments

The purpose of this study was to compare fracture resistances of K3 nickel-titanium files made from different thermal treatments. K3 (SybronEndo, Orange, CA), K3XF (SybronEndo), and experimentally heat treated K3 (K3H) were used. For the cyclic fatigue test, the samples were rotated with up-and-down motion in the artificial canal with the curvature of 60 degrees until the fracture occurred. The...

متن کامل

Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated Nickel-Titanium instruments.

AIM To compare the cyclic fatigue resistance of HyFlex CM, Twisted Files (TF), K3XF, Race, and K3, and evaluate the effect of autoclave sterilization on the cyclic fatigue resistance of these instruments both before and after the files were cycled. METHODOLOGY Five types of NiTi instruments with similar size 30, .06 taper were selected: HyFlex CM, TF, K3XF, Race and K3. Files were tested in a...

متن کامل

Phase transformation behavior and mechanical properties of thermomechanically treated K3XF nickel-titanium instruments.

INTRODUCTION The bending and torsional properties of thermomechanically treated K3XF (SybronEndo, Orange, CA) nickel-titanium instruments in relation to their phase transformation behavior were evaluated. METHODS NiTi instruments K3 (SybronEndo) and K3XF, both in sizes 25/.04 and 40/.04, were examined by differential scanning calorimetry and X-ray diffraction. The metal composition was determ...

متن کامل

Cyclic fatigue resistance of K3, K3XF, and twisted file nickel-titanium files under continuous rotation or reciprocating motion.

INTRODUCTION New designs and alloys and different motions have been introduced to increase the cyclic fatigue (CF) resistance of nickel-titanium (NiTi) files. The aim of this study was to compare the CF resistance of K3 (SybronEndo, Orange, CA), K3XF (SybronEndo), and TF (SybronEndo) files under continuous rotation and reciprocating motion. METHODS A total of 210 files (30-tip diameter, 0.06 ...

متن کامل

The Effect of Hydrofluoric Acid Surface Treatment on the Cyclic Fatigue Resistance of K3 NiTi Instruments

The aim of this study was to investigate the effect of 50% hydrofluoric acid (HF) surface treatment on the cyclic fatigue resistance (CFR) of K3 NiTi instruments. Twenty as-received and twenty HF-treated K3 NiTi instruments were compared in CFR. The surface texture and fracture surface of two instrument groups were examined with a scanning electron microscope (SEM). Additionally, any change of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endodontics

دوره 41 4  شماره 

صفحات  -

تاریخ انتشار 2015