Validation of estimates of total body water in pediatric dialysis patients by deuterium dilution.

نویسندگان

  • Susan R Mendley
  • Nancy L Majkowski
  • Dale A Schoeller
چکیده

BACKGROUND Current K-DOQI recommendations call for an assessment of dialysis adequacy that depends critically on an estimate of total body water (TBW). Such estimates are problematic in children since the range of patient size is large, and often formulas derived in normals are not validated in end-stage renal disease. Gold standard methods of TBW measurement, such as deuterium dilution ((2)H(2)O), are not appropriate in the clinical setting, yet noninvasive methods such as bioimpedance analysis (BIA) and dual energy x-ray absorptiometry (DEXA) have not been independently validated. METHODS We studied 14 stable pediatric dialysis patients on 1 to 3 occasions using (2)H(2)O dilution, BIA, DEXA, and anthropometry to measure TBW. We compared our data set to previously published formulae for TBW to determine root mean square error (RMSE) and skew of the estimate. RESULTS TBW prediction based upon the anthropometric formula proposed by the Pediatric Peritoneal Dialysis Consortium provided the best fit to our independent data set with RMSE = 2.15 L, and no skew by Bland-Altman analysis. Other formulas produced large, clinically relevant errors; obese subjects confounded many estimates. TBW calculated from hydrated lean body mass from DEXA scan was reliable with RMSE = 1.03 L and no skew. BIA-derived estimates can be useful, although the magnitude of RMSE ranged from 1.45 to 6.24 L, and one formula produced skewed results. CONCLUSION Techniques for estimating TBW in pediatric dialysis patients must be validated by independent data sets before being incorporated into clinical and research practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A non-invasive, on-line deuterium dilution technique for the measurement of total body water in haemodialysis patients.

BACKGROUND Despite its importance, total body water (TBW) is usually estimated rather than measured due to the complexity of isotope dilution methods. The aim of this study was to demonstrate the applicability in haemodialysis (HD) patients of a recently developed on-line breath test, previously validated in healthy subjects, that uses the gold standard deuterium dilution method to measure TBW....

متن کامل

Assessment of fluid status in peritoneal dialysis patients.

OBJECTIVES To assess the influence of abnormalities in fluid status and body composition on agreement between multifrequency bioimpedance analysis (MF-BIA), segmental BIA (sigmaBIA), the Watson formula, and tracer dilution techniques. DESIGN Cross-sectional. SETTING Multicenter. PATIENTS 40 patients (29 males, 11 females) on peritoneal dialysis (PD). MAIN OUTCOME MEASURES Agreement betw...

متن کامل

Volaemic assessment of the elderly hyponatraemic patient: reliability of clinical assessment and validation of bioelectrical impedance analysis.

BACKGROUND Hyponatraemia is the commonest electrolyte disturbance of hospital inpatients. Assessment of volaemic status is an important part of diagnosis and management. AIM To determine reliability of clinical assessment of volaemic state by assessing inter-observer variability of clinical measures of volaemic state. To assess validity of bioelectrical impedance analysis as a tool to measure...

متن کامل

Comparison of anthropometric equations for estimation of total body water in peritoneal dialysis patients.

BACKGROUND Several formulae exist for estimating total body water (TBW). We aimed to assess their validity in peritoneal dialysis patients by comparison with TBW estimated by deuterium oxide dilution (TBW(D)). METHODS We compared the equations of Chertow (TBW(Cher)), Chumlea (TBW(Chum)), Hume and Weyers (TBW(HW)), Johansson (TBW(J)), Lee (TBW(L)), Watson (TBW(W)) and TBW as 58% of body weight...

متن کامل

Use of Urea and Deuterium Oxide to Measure Body Composition'

The use of dilution of urea or deuterium oxide ( D 2 0 ) to estimate body water in cattle, sheep and pigs is reviewed. After equilibration, which requires about 20 min after infusion of urea and 4 to 6 h after infusion of D 2 0 , urea and D , 0 space estimated from dilution in water of blood are each closely related to total body water. Calculation of body composition from total body water can ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kidney international

دوره 67 5  شماره 

صفحات  -

تاریخ انتشار 2005