[Asymmetric intrastromal corneal ring for the treatment of keratoconus].
نویسندگان
چکیده
PURPOSE To analyze corneal curvature and visual acuity after asymmetric intrastromal corneal rings implantation, not following the nomogram proposed by the manufacturer. METHODS Seven eyes of seven keratoconus patients which had asymmetric corneal rings implanted in their corneal stroma were studied. RESULTS A flattening of the average corneal keratometry was noted in all patients, as well as an increase of the postoperative corneal asymmetry. CONCLUSIONS Asymmetric intrastromal corneal ring implant improves the postoperative visual acuity with and without correction. As a result we noticed flattening of the corneal curvature at the thicker ring implantation spot and increase of corneal asymmetry.
منابع مشابه
Comparative Results in a Combined Procedure of Intrastromal Corneal Rings Implantation and Cross-linking in Patients with Keratoconus: A Retrospective Study
INTRODUCTION Corneal thinning disorders caused by keratoconus often lead to protrusion, irregular astigmatism, and even perforation. Keratoconus, like other corneal ectasia, does not have a known cause. Severe cases of keratoconus may require correction or restoration of tectonic integrity of the cornea by surgical means. Intracorneal ring segments are a new modality in the treatment of corneal...
متن کاملHypocellular scar formation or aberrant fibrosis induced by an intrastromal corneal ring: a case report
INTRODUCTION Intrastromal corneal rings or segments are approved for the treatment of myopia and astigmatism associated with keratoconus. We describe a clinicopathological case of intrastromal corneal rings. For the first time, the molecular pathological findings of intrastromal corneal rings in the cornea are illustrated. CASE PRESENTATION A 47-year-old African-American man with a history of...
متن کاملFerrara intrastromal corneal rings for the correction of keratoconus.
PURPOSE To evaluate the safety and efficacy of Ferrara intrastromal corneal rings in the treatment of eyes with keratoconus without central corneal scarring. SETTING Vlemma Eye Institute, Athens, Greece. METHODS Twenty-six patients with bilateral keratoconus, clear central corneas, and contact lens intolerance participated in the study. Videokeratographic corneal topography and ultrasonic p...
متن کاملLong-term Follow-up of Ferrara Rings Segments for the Treatment of Keratoconus
Purpose: To evaluate the long-term results of Ferrara rings intracorneal ring segments for the treatment of keratoconus. Setting: Private medical center, Ophthalmology Department, Hadassah Optimal Medical Center, Haifa, Israel. The National Center for the Treatment of Keratoconus Haifa, Israel. Materials and methods: Retrospective review of data for patients implanted with Ferrara intrastromal ...
متن کاملRefractive Surgery Feature Story
JUNE 2010 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 23 A s we reported in the Journal of Cataract and Refractive Surgery,1 use of a thick intrastromal corneal ring segment (ICRS) may enhance the surgical effect in patients with keratoconus. Although commercially available ICRSs are limited in thickness, one can achieve the effect of thicker segments by stacking two within a single intrastromal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 73 5 شماره
صفحات -
تاریخ انتشار 2010