Towards using scattered PET emission data for reconstruction of attenuation map in PET/MRI

نویسندگان

  • Yannick Berker
  • Volkmar Schulz
چکیده

Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany Despite promising advances, attenuation correction of PET data remains challenging in PET/MRI. Known approaches to estimating attenuation maps from PET emission data take into account only true coincidences and fail to completely determine the attenuation map without prior information. Even TOF PET emission data determines the attenuation sinogram up to an unknown constant only. We propose to extract information from scattered PET coincidences to fully determine the attenuation map. Scatter-to-attenuation reconstruction has been approximated by a proof-of-concept scatter-to-attenuation back-projection. The latter is based on determining possible scattering locations from energy measurements (via Compton scattering angles) and summing contributions from scattered coincidences in image voxels. Contributions are weighted based on geometrical considerations and various corrections derived from a scatter-measurement equation similar to the single-scatter-simulation formula; this equation represents a weighted Radon transform on surfaces in curvilinear coordinates. The back-projection technique was evaluated with data from GATE simulations of various activity and attenuation distributions in a clinical scanner model. Finally, the potential of the back-projection operator for determination of a unique attenuation map has been evaluated in an iterative scheme for small-scale problems. Scatter-to-attenuation back-projection of coincidences with scattered photon energies in the range of 248–478 keV are shown for general cases as well as for highly degenerate cases with perfect spherical symmetry of attenuation and activity distributions. The parameter-space trajectory followed by the iterative scheme shows that the proposed scatter-to-attenuation back-projection can be used to estimate true attenuation values despite an initially unknown scaling factor. Scattered coincidences provide information that may complement existing reconstruction approaches. The proposed scatter-to-attenuation back-projection may constitute a missing piece for resolving ambiguities in the simultaneous reconstruction of activity and attenuation. Lacking an analytical reconstruction procedure, iterative techniques need to be developed to fully integrate information from true and scattered coincidences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR-guided joint reconstruction of activity and attenuation in brain PET-MR

With the advent of time-of-flight (TOF) PET scanners, joint maximum-likelihood reconstruction of activity and attenuation (MLAA) maps has recently regained attention for the estimation of PET attenuation maps from emission data. However, the estimated attenuation and activity maps are scaled by unknown scaling factors. We recently demonstrated that in hybrid PET-MR, the scaling issue of this al...

متن کامل

Simultaneous reconstruction of attenuation and activity in ToF PET/MRI with additional transmission data

MEDISIP Medical Imaging and Signal Processing Group, Ghent University, IBBT-IBiTech, iMinds Medical IT, Ghent, Belgium In Time-of-Flight PET/MRI systems accurate attenuation correction, based on the MRI image, is not straight forward. An alternative is attenuation correction based on emission data only. This is for instance done by simultaneous reconstruction of attenuation and activity with th...

متن کامل

Attenuation Correction Synthesis for Hybrid PET-MR Scanners

The combination of functional and anatomical imaging technologies such as Positron Emission Tomography (PET) and Computed Tomography (CT) has shown its value in the preclinical and clinical fields. In PET/CT hybrid acquisition systems, CT-derived attenuation maps enable a more accurate PET reconstruction. However, CT provides only very limited soft-tissue contrast and exposes the patient to an ...

متن کامل

Automated body-lung-air material map segmentation from pre-clinical MRI images for PET attenuation correction in Tera-Tomo 3D PET reconstruction engine of nanoScan PET/MRI system

Department of Software Engineering, Mediso Ltd., Budapest, Hungary The aim of current work was to automatically derive a body-lung-air three-valued material map from MRI images for pre-clinical PET attenuation correction. Our goal was also to measure the effect of attenuation on corresponding pre-clinical PET images. 12 mouse and 9 rat PET/MRI images were acquired by nanoScan PET/MRI (Mediso). ...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014