Evaluation of a novel dry latex preparation for demonstration of infectious mononucleosis heterophile antibody in comparison with three established tests.

نویسندگان

  • R Rogers
  • A Windust
  • J Gregory
چکیده

A new, dried antigen-coated latex preparation for the demonstration of infectious mononucleosis (IM) heterophile antibody (Dryspot IM kit; Oxoid, Ltd., Basingstoke, Hampshire, United Kingdom) was compared with the IM kit (a liquid latex reagent from the same source), an immunoassay (ImmunoCard Mono; Meridian Diagnostics), and an absorption test (Monospot; Meridian Diagnostics). The latter was used as a standard for initial statistical comparisons. Discrepancies were resolved by using Epstein-Barr virus serology. Of the 328 routine samples tested, 77 were positive and 222 were negative by all IM heterophile antibody-based kits. Twenty-nine samples gave discrepant results. Following resolution of discrepant results, the sensitivity and specificity values for the IM Dryspot kit were 87.0 and 98.7%, those for the Oxoid liquid latex IM kit were 83.0 and 99.6%, and those for the ImmunoCard Mono immunoassay were 85.0 and 100.0%, respectively. The evaluation shows that the Dryspot kit, which is uniquely straightforward to use and may be stored at room temperature, is comparable in performance to other rapid heterophile tests for the confirmation of IM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of three commercial tests for detection of heterophile antibody in patients with infectious mononucleosis.

Infectious mononucleosis (IM) is caused by the Epstein-Barr virus. Commonly used laboratory tests used for diagnosis of IM include a screening test based on the observation that horse erythrocytes are agglutinated by the Paul-Bunnell antibody found in the serum of patients with IM. This study evaluated two latex agglutination (LA) kits for IM, Monolatex (Wampole Laboratories) and Immunoscan-IM ...

متن کامل

Horse erythrocyte glycoprotein-latex reagent that reacts with infectious mononucleosis heterophile antibody.

A sialoglycoprotein from horse erythrocytes was isolated in essentially homogeneous form and found to contain the neuraminidase-sensitive determinant of the horse erythrocyte for Paul-Bunnell heterophile antibodies of infectious mononucleosis. This reactivity was retained after covalent coupling of the antigen to latex particles. The latex reagent has greater stability (greater than 3 years) th...

متن کامل

Serodiagnosis of infectious mononucleosis with a bovine erythrocyte glycoprotein.

A glycoprotein from bovine erythrocyte membrane was evaluated in two immunoassays as a reagent for the serodiagnosis of infectious mononucleosis (IM). We previously reported that a partially purified preparation of this glycoprotein, when attached to latex beads, agglutinated in the presence of IM heterophile antibody. In the present study, we used a highly purified form of the glycoprotein bot...

متن کامل

Hematologic differences in heterophile-positive and heterophile-negative infectious mononucleosis.

Infectious mononucleosis (IM) due to all causes is characterized by atypical lymphocytosis. We sought to compare hematologic parameters of infectious mononucleosis due to Epstein-Barr virus (EBV) infection (heterophile antibody (HA) positive) with mononucleosis due to other causes. Mono-Latex Slide Agglutination Test results and complete blood counts (CBC) of 147 patients with mononucleosis wer...

متن کامل

Evaluation of latex-based heterophile antibody assay for diagnosis of acute infectious mononucleosis.

The diagnosis of an acute episode of infectious mononucleosis (IM) is made on the basis of clinical symptoms and serological evidence for development of heterophile antibodies. In an effort to obtain a very sensitive and specific assay for diagnosis of IM, we have developed MERISTAR:IM. The MERISTAR assay uses latex beads coated with purified bovine heterophile antigen. We compared the sensitiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 37 1  شماره 

صفحات  -

تاریخ انتشار 1999