A small artery heat transfer model for self-heated thermistor measurements of perfusion in the kidney cortex.

نویسندگان

  • G T Anderson
  • J W Valvano
چکیده

A small artery model (SAM) for self-heated thermistor measurements of perfusion in the canine kidney is developed based on the anatomy of the cortex vasculature. In this model interlobular arteries and veins play a dominant role in the heat transfer due to blood flow. Effective thermal conductivity, kss, is calculated from steady state thermistor measurements of heat transfer in the kidney cortex. This small artery and vein model of perfusion correctly indicates the shape of the measured kss versus perfusion curve. It also correctly predicts that the sinusoidal response of the thermistor can be used to measure intrinsic tissue conductivity, km, in perfused tissue. Although this model is specific for the canine kidney cortex, the modeling approach is applicable for a wide variety of biologic tissues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of the Weinbaum-Jiji model of blood flow in the canine kidney cortex for self-heated thermistors.

The Weinbaum-Jiji equation can be applied to situations where: 1) the vascular anatomy is know; 2) the blood velocities are known; 3) the effective modeling volume includes many vessels; and 4) the vessel equilibration length is small compared to the actual length of the vessel. These criteria are satisfied in the situation where steady-state heated thermistors are placed in the kidney cortex. ...

متن کامل

Transient Three-Dimensional Thermal Analysis of a Slab with internal heat generation and heated by a Point Moving Heat Source

In this work, analysis of transient three-dimensional heat transfer in a slab with internal heat generation and heated by a point moving heat source along its axis is carried out using integral transforms methods. The heat input into slab or workpiece by the moving heat source is considered in the model. From the results, it was established that the temperature of the material during the heat t...

متن کامل

A New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System

Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...

متن کامل

Heat Transfer and Carryover in the Dryout of a Heated Vertical Tube

This work concerns dryout experiments in which a tube, initially containing water, filled up or partially filled and at 1,2 or 3 atmosphere pressures, is heated. The initial water column experience three thermal regions. The first region, called the first period, involves heating of the tube until saturation conditions are obtained in the water. Boiling of the water in the tube causes swelling ...

متن کامل

Convective Heat Transfer from a Heated Rotating Disk at Arbitrary Inclination Angle in Laminar Flow

In this paper, experimental data and numerical results of heat transfer from a heated rotating disk in still air are presented over a large range of inclination angles and a dimensionless correlation is developed for forced, natural and mixed convection. The measured Nusselt number over the rotating disk is compared with the numerical results. The goal of the present research is to develop a se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 116 1  شماره 

صفحات  -

تاریخ انتشار 1994