Calibration Studies of the Drum Impactor*
نویسندگان
چکیده
A b s t r a e t ~ l i b r a t i o n studies were performed on the Davis Rotating-drum Universal-size-cut Monitoring (DRUM) sampler utilizing fluorescent monodisperse aerosols of polystyrene latex. The DRUM sampler is an eight-stage Lundgren-type rotating drum cascade impactor utilizing a series of single round jets for each stage including low-pressure stages. The DRUM sampler operates continuously for up to 2 weeks with particle collection on slowly rotating, greased substrate-coated cylindrical drums. The resulting narrow linear deposit for each stage can be evaluated with time resolution as short as 4 h utilizing Particle Induced X-ray Emission (PIXE) spectroscopy and other analytical methods. The DRUM sampler is particularly useful for evaluating environmental aerosols for size-related chemical properties. Aerosols of monodisperse fluorescent polystyrene latex spheres were generated by nebulization from dilute aqueous suspensions, dried with a diffusion drier, and reduced in electrostatic charge with a krypton-85 discharger. The aerosols were characterized by electron microscopy and with a Climet208 light scattering particle counter; they were quantified utilizing the fluorescent label. DRUM samples were collected at selected flow rates up to the critical 18.3 cm 3 s1, and the square root of the non-dimensionalized Stokes' number was plotted vs collection efficiency for the impactor stages. The results were in reasonable agreement with the expected effective cut-offaerodynamic diameters based on the non-dimensionalized theory of Marple and with the data of Mercer. All the stages demonstrated dynamic similarity when the Stokes' numbers were calculated at the reduced pressure and temperature at orifice outlets with orifice areas corrected for contraction at sonic and near sonic speeds. The measured cut-offvalues for another low pressure impactor were verified with these results. A wall loss study was conducted using polydisperse respirable aerosols of ammonium fluorescein generated by nebulization with a Lovelace nebulizer, dried with a diffusion drier, and reduced to Boltzmann equilibrium with a krypton-85 discharger. The results show wall losses to be about 10.7 % of the sample.
منابع مشابه
Efficiency Calibration Studies for Gamma Spectrometric Systems: the Influence of Different Parameters
The radioactive waste containers, containing different radioactive materials, have to be characterized before their final disposal. Destructive methods, although being the most precise, are also the most expensive and not the easiest ones from the radioprotection point of view. In this situation, high resolution gamma spectrometry proved to be a reliable method for the non destructive assay met...
متن کاملA finite element model to simulate magnetic field distribution and laboratory studies in wet low-intensity magnetic separator
Low-intensity magnetic separators are widely used in the research works and the industry. Advancement in the magnetic separation techniques has led to an expansion in the application of this method in different fields such as enrichment of magnetic mineral, wastewater treatment, and medicine transfer in the human body. In the mineral processing industry, the main application of wet magnetic sep...
متن کاملNarrative Vagueness in Grass’s The Tin Drum: A Text-Centric Model of Narration to Reveal Dialogized Heteroglossia
The present study sets out to investigate the narrator’s textual position in Grass’s The Tin Drum. Although authorial self-dramatization through affinities with one or more characters in the work is undeniable, this study mainly concentrates on the inner interpenetrations of heteroglot utterances as uttered by an unreliable first-person narrator, Oskar Matzerath, in the light of the Bakhtinian ...
متن کاملNonlinear Modelling of Kerman Combined Cycle Power Plant Drum-Boiler and Drum Level control especially in trip conditions
There are various methods of power generation such as combined cycle power plants. There are many variables in a power plant boiler unit, but the most important variables are Pressure and specially drum level that control system should be put it in the safe range. The purpose of this article is, modifying the oscillatory behavior of the drum level of Kerman combined cycle power plant and especi...
متن کاملThe Use of STIM and PESA to Measure Proles of Aerosol Mass and Hydrogen Content, Respectively, across Mylar Rotating Drums Impactor Samples
A method has been developed for measuring pro les of aerosol mass on thin (480 1g/cm2) Apiezon-L coatedMylar lms employed in rotating drum aerosol impactor samplers using the ion beam analysis technique scanning transmission ion microscopy (STIM). The greased Mylar lms are excellent impaction substrates and possess excellent uniformity in projected density, making them an ideal substrate f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -