Optimized heat transfer correlations for pure and blended refrigerants
نویسندگان
چکیده
Refrigerant blends and pure refrigerants have wide applicability in thermal engineering. One of the critical parameters in the design and evaluation of thermal equipment is the heat transfer coefficient, which can be difficult to determine for refrigerants that undergo phase change within the equipment. For pure refrigerants, classical experimental relations developed by Gungor and Winterton (GW87) are known to exhibit errors around 15% on average, and reaching more than 40% in some cases. For refrigerant blends larger uncertainties are expected due to a complex number of factors such as nucleate boiling degradation, particularly when using functional forms previously developed for pure refrigerants. This work provides a comprehensive experimental study on the determination of heat transfer coefficients for R-22, R-134a, and the predefined refrigerant blends R-404A and R-407C. Genetic optimization is used to obtain more accurate semi empirical relations based on the classical GW87 correlation, and results of the optimization analysis show large improvement for pure refrigerants. The use of a degradation factor in the optimized correlation for R-407C allows for substantial error reduction for refrigerant blends. ! 2015 Elsevier Ltd. All rights reserved.
منابع مشابه
Experimental Investigation in Pool Boiling Heat Transfer of Pure/Binary Mixtures and Heat Transfer Correlations
Nucleate pool boiling heat transfer coefficient have been experimentally measured on a horizontal rod heater for various liquid binary mixtures. Measurements are based on more than three hundred data points on a wide range of concentrations and heat fluxes. In this investigation, it has been confirmed that the heat transfer coefficient in boiling solutions are regularly less than those in p...
متن کاملUncertainty Analysis on Prediction of Heat Transfer Coefficient and Pressure Drop in Heat Exchangers Due to Refrigerant Property Prediction Error
Numerical simulation is extensively used in heat exchanger design and performance evaluation. While evaluating potential working fluids, pure fluids and fluid mixtures with different component combinations and fractions are compared based on simulation results. Two of the challenges while conducting such studies are the uncertainties of refrigerant properties and the applicability of empirical ...
متن کاملPool boiling heat transfer coefficient of pure liquids using dimensional analysis
The pool boiling heat transfer coefficient of pure liquids were experimentally measured on a horizontal bar heater at atmospheric pressure. These measurements were conducted for more than three hundred data in thermal currents up to 350 kW.m-2. Original correlations and the unique effect of these correlations on experimental data were discussed briefly. According to the analysis, a new empirica...
متن کاملHeat Transfer Coefficients and Transport Properties for Alternative Refrigerants
Practical and empirical equations of transport properties have been developed for refrigerant compounds. These equations have been used to develop correlations for experimental heat transfer coefficient (IITC) for both evaporation and condensation in smooth tubes. Model calculations have been compared with recent experimental data, and reasonable agreement has been obtained. INTRODUCTION We hav...
متن کاملEvaporation and Condensation Heat Transfer Performance of Flammable Refrigerants in a Brazed Plate Heat Exchanger
Average Nusselt numbers were measured for R22, R290, R290/600a, and R32/152a undergoing evaporation and condensation in a brazed plate heat exchanger. The refrigerants experienced wavy, stratified flow at low heat and mass fluxes, 1.3 kW/m2 to 8.3 kW/m2 and 1.6 kg/m2 s to 19 kg/m 2 s, respectively. Heat transfer correlations from the literature for in-tube and channel flow of refrigerants with ...
متن کامل