Validation of the in vivo volumetric wear measurement for total knee prostheses in model-based RSA.

نویسندگان

  • E A van Ijsseldijk
  • B Lebel
  • B C Stoel
  • E R Valstar
  • S Gouzy
  • C Vielpeau
  • B L Kaptein
چکیده

Implant failure related to polyethylene wear remains an important issue in total knee arthroplasty. Polyethylene wear is usually assessed in vivo by measuring the remaining insert thickness on X-ray images of the knee. To reflect the amount of wear debris more accurately, a 3-dimensional overlap measurement has been suggested, which is based on implant component models which are matched on calibrated stereo X-ray images using model-based roentgen stereophotogrammatic analysis. The goal of this study was to determine the influence of pose estimation, insert thickness deviation and variation in the femoral-tibial contact location on the accuracy and precision of the measurement using simulations and a phantom experiment. We found that the pose estimation was the largest source of variation. The 95% prediction interval varied between 111 and 283 mm(3), which is approximately 100-200% of the detected volumetric wear. Insert thickness variation resulted in prediction intervals of 74-174 mm(3). Variation of the femoral-tibial contact location in the phantom experiment gave a prediction interval of 40 mm(3). Large differences in the detected wear volume were found for different flexion angles. At most 56% of the true wear volume was detected (129 of 230 mm(3), 30° of flexion). In summary, both the accuracy and precision of the volumetric wear measurement were low. The prediction interval of the volumetric wear measurement is at least as large as the measurement outcome itself. This is an important limitation to the applicability of the volumetric wear measurement in clinical practice and further clinical validation is required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of polyethylene wear in anatomical and reversed shoulder prostheses.

Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movemen...

متن کامل

Determining material loss from the femoral stem trunnion in hip arthroplasty using a coordinate measuring machine.

In contrast to the articulating and taper surfaces of failed total hip replacements, volumetric wear analysis of trunnions is not routinely performed. Metal wear particles from the trunnion may contribute not only to the failures of metal-on-metal total hip replacements but also to all hip replacements utilising metal trunnions. A validation study was performed with the material removed in stag...

متن کامل

The effect of insert conformity and material on total knee replacement wear

The mean average life is increasing; therefore, there is a need to increase the lifetime of the prostheses. To fulfil this requirement, new prosthetic designs and materials are being introduced. Two of the design parameters that may affect wear of total knee replacements, and hence the expected lifetime, are the insert conformity and material. Computational models have been used extensively for...

متن کامل

Digital Roentgen Stereophotogrammetry : Development , Validation , and Clinical Application

Contents 1 General introduction 9 2 RSA in practical steps 19 3 RSA of the Mallory-Head femoral stem without attached markers 33 4 Roentgen stereophotogrammetric analysis of metal-backed hemispherical cups without attached markers 49 5 Fast and accurate automated measurements in digitised stereophotogrammetric radiographs 59 6 Digital automated RSA compared to manually operated RSA 75 7 Model-b...

متن کامل

Validation of a model-based measurement of the minimum insert thickness of knee prostheses

INTRODUCTION Wear of polyethylene inserts plays an important role in failure of total knee replacement and can be monitored in vivo by measuring the minimum joint space width in anteroposterior radiographs. The objective of this retrospective cross-sectional study was to compare the accuracy and precision of a new model-based method with the conventional method by analysing the difference betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 46 7  شماره 

صفحات  -

تاریخ انتشار 2013