Plasma sodium concentration: bearer of false prophecies?

نویسنده

  • H G Worth
چکیده

Occasionally measurement of the serumn or plasma concentration of sodium may give rise to falsely low results when carried out on a flame photometer or by an indirect reading ion selective electrode. The patients at risk are those with abnormally high serum concentrations of lipid or protein. These are, however, few: initially all low sodium concentrations as measured by flame photometry should be regarded as genuine. Measurement of the sodium concentrations of large numbers of specimens of serum or plasma became possible in routine clinical chemistry laboratories some 35 years ago with the advent of the flame photometer.' Before that, measurement of sodium was laborious, time consuming, and imprecise-and the same was true of potassium, measurement of which is equally suited to flame photometry. Indeed this technique had a virtual monopoly until suitable ion selective electrodes became available.2 As with many new techniques there are good arguments for and against change, but in this instance the physical principle of measurement differs-a fact which must be understood and taken into account by the clinical chemist. These technicalities do not usually concern or interest the clinician unless they affect the reported result to a substantial extent. Such variation may occur with measurements of serum concentrations of sodium, and both clinicians and clinical chemists need to be aware of the relevant circumstances. The measurement of sodium by flame photometry determines the number of sodium atoms in a defined unit volume of serum or plasma. The ion selective electrode, by contrast, determines the activity of sodium in the solution rather than its concentration. The concept of activity is one which is familiar to physical chemists but less so to medical scientists and clinicians. It may best be described as a measure of the number of atoms which act truly and wholly as ions in a defined unit volume of electrolytic solution. The difference between concentration and activity is reduced as the solution becomes more dilute. In other words, the difference is less in a plasma sample which has been diluted, say, 1 in 200, before measurement than in the same undiluted sample. Several factors contribute to the difference between concentration and activity, and these vary in magnitude among different specimens of plasma. The main factor of clinical relevance is the volume occupied by lipid and protein. Because lipids and proteins exclude water the volume they occupy is not 0 BRI[[SH MEL)ICAI. JOURNAL 1983. All …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-Fulfilling Prophecies: Mechanisms, Power, and Links to Social Problems

A core theme of social psychology is that perceivers can shape targets’ future behaviors through self-fulfilling prophecies. Self-fulfilling prophecies occur when perceivers’ false beliefs about targets initiate a sequence of events that ultimately cause targets to exhibit expectancy-consistent behaviors, thereby causing perceivers’ initially false beliefs to become true. This article reviews t...

متن کامل

Bioequivalence of sodium valproate tablets manufactured in Iran compared to its foreign counterpart

    In this double blind crossover study we assessed the bioequivalence of 200 mg enteric coated sodium valproate tablets manufactured by Roozdarou with 200 mg enteric coated sodium valproate (Orlept) manufactured by Desitin, Germany. Twelve healthy male volunteers were administered a single dose of 600 mg sodium valproate manufactured by Roozdarou, followed by a similar dose of Orlept, 2 weeks...

متن کامل

Effect of KOH concentration on the microstructure and electrochemical behavior of ceramic coatings formed by plasma electrolytic oxidation method on AZ31B Mg alloy

In this study, ceramic coatings were prepared on AZ31B Mg alloy by plasma electrolytic oxidation technique in electrolytes containing sodium fluoride (KF), sodium silicate (Na2SiO3.5H2O) and different potassium hydroxide (KOH) concentrations. The electrochemical behavior of AZ31B alloy and plasma electrolytic oxidation coatings was studied by potentiodynamic polarization, electrochemical impeda...

متن کامل

Inventing Partners in Computer-Mediated Communication: How CMC Sustains Self-fulfilling Prophecies and Relational Attributions

Research on computer-mediated communication (CMC) vacillates between arguments that the medium of text is too barren to experience partners’ personalities, to claims that we “fill in the blanks” when encountering others online. This metaphor of filling in the blanks can be substantiated scientifically by examining data from several studies that demonstrate when and how CMC users form idealized ...

متن کامل

Indeterminate Truth

Can a truth-bearer be true but not determinately so? On the enduringly popular standard supervaluational conception of indeterminacy, under which the principle of bivalence is invalid, the answer is a straightforward No. On such a conception, truth just is determinate truth—truth in all admissible interpretations. For that reason, a more interesting question is: can a truth-bearer be true but n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British medical journal

دوره 287 6392  شماره 

صفحات  -

تاریخ انتشار 1983