Subjective and objective evaluation of image quality in biplane cerebral digital subtraction angiography following significant acquisition dose reduction in a clinical setting.

نویسندگان

  • Amir R Honarmand
  • Ali Shaibani
  • Tamila Pashaee
  • Furqan H Syed
  • Michael C Hurley
  • Christina L Sammet
  • Matthew B Potts
  • Babak S Jahromi
  • Sameer A Ansari
چکیده

OBJECTIVE Different technical and procedural methods have been introduced to develop low radiation dose protocols in neurointerventional examinations. We investigated the feasibility of minimizing radiation exposure dose by simply decreasing the detector dose during cerebral DSA and evaluated the comparative level of image quality using both subjective and objective methods. METHODS In a prospective study of patients undergoing diagnostic cerebral DSA, randomly selected vertebral arteries (VA) and/or internal carotid arteries and their contralateral equivalent arteries were injected. Detector dose of 3.6 and 1.2 μGy/frame were selected to acquire standard dose (SD) and low dose (LD) images, respectively. Subjective image quality assessment was performed by two neurointerventionalists using a 5 point scale. For objective image quality evaluation, circle of Willis vessels were categorized into conducting, primary, secondary, and side branch vessels. Two blinded observers performed arterial diameter measurements in each category. Only image series obtained from VA injections opacifying the identical posterior intracranial circulation were utilized for objective assessment. RESULTS No significant difference between SD and LD images was observed in subjective and objective image quality assessment in 22 image series obtained from 10 patients. Mean reference air kerma and kerma area product were significantly reduced by 61.28% and 61.24% in the LD protocol, respectively. CONCLUSIONS Our study highlights the necessity for reconsidering radiation dose protocols in neurointerventional procedures, especially at the level of baseline factory settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation Dose Reduction without Compromise to Image Quality by Alterations of Filtration and Focal Spot Size in Cerebral Angiography

OBJECTIVE Different angiographic protocols may influence the radiation dose and image quality. In this study, we aimed to investigate the effects of filtration and focal spot size on radiation dose and image quality for diagnostic cerebral angiography using an in-vitro model and in-vivo patient groups. MATERIALS AND METHODS Radiation dose and image quality were analyzed by varying the filtrat...

متن کامل

Reduction of patient motion artifacts in digital subtraction angiography: evaluation of a fast and fully automatic technique.

The performance of an automatic technique for the reduction of patient motion artifacts in digital subtraction angiography was evaluated. Four observers assessed the quality of 104 cerebral digital subtraction angiographic images that were processed by means of both the automatic technique and manual pixel shifting. The automatic technique resulted in better image quality and was considerably l...

متن کامل

CTPA protocol optimisation audit: challenges of dose reduction with maintained image quality.

AIM To assess computed tomography (CT) pulmonary angiography (CTPA) dose and image quality in a large teaching hospital, and subsequently, to optimise the protocol in order to reduce the dose without affecting image quality. MATERIALS AND METHODS Dose-length product (DLP), patient size, and objective quality parameters (contrast-to-noise ratio and signal-to-noise ratio on standardised levels)...

متن کامل

Image Quality and Entrance Surface Dose Evaluation of Lateral Cervical Spine: A Study Using Grid and Non-Grid Techniques

Introduction: The purpose of this study is to investigate the effects of grid and non-grid techniques in the lateral cervical spine radiography on image quality and entrance surface dose (ESD). Although image quality and radiation doses have been studied by researchers, there is still a dearth of information on image quality and patient dose with different techniques. Material and Methods: The...

متن کامل

Evaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz

Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurointerventional surgery

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 2017