[Assessment of ECG-gated myocardial SPECT analysis program with cardiac phantom and clinical data].
نویسندگان
چکیده
PURPOSES ECG-gated myocardial SPECT program (QGS) is coming into wide use. This program permits measurement of end-diastolic volume (EDV), and end-systolic volume (ESV) and ejection fraction (EF) by automatic detection of myocardial edges. We assessed the reproducibility, accuracy, factors that affect the measurement of these indices using a cardiac phantom and clinical data. METHODS In the phantom study, we evaluated the effects of ventricular volume, location, absorption, acquisition time, enlarged acquisition and pre-filter on the calculated indices. In the clinical study using 99mTc-MIBI, reproducibility between 2 observers, comparison with left ventriculography and effects of pre-filter were assessed. In clinical cases of 201TI and 123I-BMIPP, left ventricular volume and EF were also analyzed by QGS with various pre-filters. RESULTS Although the true phantom volumes (y) and calculated volumes (x) showed an excellent linear correlation (y = 0.94x - 13.8, r = 0.999), calculated volumes were significantly under-estimated by 14.5-33.8%. An absorbent material around the phantom caused reduction in calculated volumes by 4.1-9.1%. Duration of acquisition times, 3 to 60 seconds per projection, did not influence the calculation of the parameters. With enlarged data collection, calculated volume (37 ml) was larger than that of normal acquisition (33 ml). When the cut-off frequency of Butterworth filter was changed, these indices of volume and EF were almost stable over 0.41 cycle/cm. There was an excellent correlation in intra-observer measurements for EDV (r = 0.998, p < 0.0001), ESV (r = 0.998, p < 0.0001) and EF (r = 0.995, p < 0.0001). In comparison with left ventriculography, correlation of parameters was good in ESV (r = 0.91, p < 0.0001), EF (r = 0.88, p < 0.0001), but was fair in EDV (r = 0.78, p < 0.0001). The QGS program underestimated EDV, ESV and EF. CONCLUSION QGS program with gated SPECT is useful to calculate relative volume and EF. However, to calculate absolute values, we should understand the various factors that affect the result of QGS.
منابع مشابه
Comparison of the myocardial perfusion and wall motion results by ECG-Gated 99mTc-MIBI SPECT, before and after CABG for evaluation of myocardial viability [Persian]
It is of value to determine the amount of viable myocardial tissue in patients suffering from chronic coronary artery disease and ventricular dysfunction. Having the capability of evaluating both myocardial perfusion and function, simultaneously, myocardial scanning by ECG-Gated is an appropriate method for this purpose. The aim of this study was to compare the results of myocardial perfu...
متن کاملThe prognostic value of stress/rest gated myocardial perfusion SPECT in patients with known or suspected coronary artery disease
Introduction:Gated myocardial perfusion SPECT has diagnostic and prognostic values in coronary artery disease (CAD). We tried to determine prognostic values of the left ventricular perfusion & functional indices as well as transient left ventricular dilation (TID) derived from gated myocardial perfusion SPECT. Methods: 1820patients who underwent gated myo...
متن کاملDiastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملThe influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...
متن کاملEvaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software
Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kaku igaku. The Japanese journal of nuclear medicine
دوره 36 4 شماره
صفحات -
تاریخ انتشار 1999