Serum creatinine determination by high performance liquid chromatography and five automated chemistry analyzers.
نویسندگان
چکیده
A sensitive and specific procedure is described for the determination of serum creatinine by reverse phase high performance liquid chromatography. The method involves sample pretreatment with a cation exchange resin followed by the isocratic separation of creatinine and an external standard which are detected by their absorbances at 254 nm. The analytical recovery of creatinine from serum was 99.8 +/- 4.9 percent using this method. The between-day coefficients of variation for creatinine concentrations of 0.83 and 8.63 mg per dl were 3.07 percent and 3.2 percent, respectively. Results obtained with this reference method were compared to results obtained with five automated chemistry analyzers. The results showed that while the comparison methods correlated well with the reference method (r greater than 0.98 in all cases), those comparison methods based on the Jaffe reaction showed negative biases. In some cases, these biases were highly statistically significant. The difference between paired results obtained with some of the automated Jaffe-based assays exceeded 0.20 mg per dl in a substantial number of specimens with creatinine concentration in the range of 0.5 to 2.3 mg per dl. The measurement of acetoacetate concentrations of specimens submitted to our laboratory for serum creatine assays showed that interference by this substance with certain Jaffe-based assays could result in clinically significant false elevations in serum creatinine concentrations.
منابع مشابه
Dipyrone interference on several common biochemical tests.
We studied the effect in vitro and in vivo of dipyrone on the determination of several biochemical tests in two analyzers, a Hitachi 747 and a Kodak Ektachem 700. From studies in vitro, we found significant interference by dipyrone (P < 0.05) in the determination of creatine kinase (CK), lactate dehydrogenase (LD), uric acid, triglycerides, cholesterol, aspartate aminotransferase, alanine amino...
متن کاملDetermination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography
Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...
متن کاملInterference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods
In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...
متن کاملInterference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods
In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...
متن کاملDetermination of Serum Creatinine by Isotope Dilution Spectrometry with Liquid Chromatographic Separation Mass
Isotope dilution mass spectrometry with liquid chromatography for the determination of serum creatinine is studied. After adding labeled (15N2) creatinine to the serum, creatinine was isolated using high performance liquid chromatography. Measurements were performed by electron impact mass spectrometry with use of a direct insertion device. Analytical results of the NIST (formerly NBS) SRM seru...