The use of twin-ring Ilizarov external fixator constructs: application and biomechanical proof-of principle with possible clinical indications
نویسندگان
چکیده
BACKGROUND In peri- or intra-articular fractures of the tibia or femur, the presence of short metaphyseal bone fragments may make the application of an Ilizarov external fixator (IEF) challenging. In such cases, it may be necessary to bridge the adjacent joint in order to ensure stable fixation. The twin-ring (TR) module of circular external fixation is proposed as an alternative method that avoids joint bridging, without compromising stability of fixation. The aim of this study is to present the experimental tests performed to compare the biomechanical characteristics of the single- and TR IEF modules. The clinical application of the TR module in select patients is also presented and the merits of this technique are discussed. METHODS In this experimental study, the passive stiffness and stability of the single-ring (SR) and twin-ring (TR) IEF modules were tested under axial and shear loading conditions. In each module, two perpendicular wires on the upper surface and another two wires on the lower surface of the rings were used for fixation of the rings on plastic acetal cylinders simulating long bones. RESULTS In axial loading, the main outcome measure was stiffness and the SR module proved stiffer than the TR. In shear loading, the main outcome measure was stability, the TR module proving more stable than the SR. DISCUSSION The TR configuration, being stiffer in shear loading, may make joint bridging unnecessary when an IEF is applied. If it is still required, TR frames allow for an earlier discontinuation of bridging; either case is in favour of a successful final outcome. CONCLUSION The application of the TR module has led to satisfactory clinical outcomes and should be considered as an alternative in select trauma patients treated with an IEF. Biomechanically, the TR module possesses features which enhance fracture healing and at the same time obviate the need for bridging adjacent joints, thereby significantly reducing patient morbidity.
منابع مشابه
A biomechanical analysis of the Ilizarov external fixator.
Five configurations of the Ilizarov fixator were analyzed in vitro. The overall stiffness, shear stiffness, and axial motion of the fracture site were determined. The data were compared with the results of eight conventional one-half frame fixators previously tested in the same manner. The Ilizarov fixator allowed significantly more axial motion at the fracture site during axial compression tha...
متن کاملA Biomechanical Comparison between Taylor’s Spatial Frame and Ilizarov External Fixator
ABSTRACT Taylor's spatial frame (TSF) and Ilizarov external fixators (IEF) are two circular external fixator commonly used to address complex deformity and fractures. There is currently no data available comparing the biomechanical properties of these two external fixators. This study looks into the mechanical characteristics of each system. TSF rings with 6 oblique struts, 4 tube connectors, 4...
متن کاملResults of application of external fixation with different types of fixators.
INTRODUCTION Extra-focal or external fixation is the method of fracture fixation through the healthy part of the bone using pins or wires. OBJECTIVE The aim was to determine which external splints (Ortofix, Mitković, Charnley and Ilizarov) had the best biomechanical properties in primary stabilization of spiral, transverse and commutative bone fractures. METHODS To determine the investigati...
متن کاملManagement of shotgun induced open fractures of the humerus with Ilizarov external fixator.
BACKGROUND Our aim was to evaluate the clinical efficacy of Ilizarov external fixator used for the management of shotgun induced open humeral fractures with special emphasize on neurovascular sequelae. METHODS The authors retrospectively reviewed eleven shotgun induced open humeral fractures managed with emergent application of Ilizarov external fixator. No patient had associated neurovascula...
متن کاملA biomechanical comparison of micromotion after ankle fusion using 2 fixation techniques: intramedullary arthrodesis nail or Ilizarov external fixator.
BACKGROUND In difficult ankle arthrodesis situations, intramedullary (IM) arthrodesis nails and external fixation are often considered in lieu of standard fusion techniques. The purpose of this study was to compare the amount of micromotion measured across an ankle fusion site stabilized with either an IM nail or with the Ilizarov external fixator. MATERIALS AND METHODS The relative bone mine...
متن کامل