BACKGROUND/AIM Isolated stenosis of the lacrimal punctum is a frequent cause of epiphora. Treatment relies on surgical opening or dilatation with bi- or monocanalicular prosthesis. Recently, silicone perforated punctum plugs (PPP) were proposed. The drawback with these silicone PPP was that secretions accumulate in the central orifice blocking the spontaneous flow of tears. A modification of the surface of the PPP using polyvinylpyrrolidone (PVP) was thus proposed. The aim was to compare silicone PPP with new PVP surface treated PPP. METHODS A prospective study was conducted of 20 patients with dilatable stenosis of the lacrimal puncta who developed epiphora. Epiphora, tolerance, implantation of the PPP, and lacrimal drainage were evaluated using scintigraphy of the lacrimal ducts. RESULTS The raw data and statistical analysis showed evidence of a superior performance of PVP surface treated PPP. CONCLUSION Long term evaluation of the advantages or risks of PVP plugs and comparison with microsurgical punctoplasty are warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of the Silicone Ring Tourniquet and Standard Pneumatic Tourniquet on the Motor Nerve Conduction, Pain and Grip Strength in Healthy Volunteers

  Background: The pneumatic tourniquet (PT) is routinely used in upper and lower limb operations by most orthopaedic surgeons. The silicone ring tourniquet (SRT) was introduced in clinical practice the last decade. Clinical as well comparative studies in volunteers concerning its safety and efficacy have been published. The aim of this study was to investigate the postoperative effect of the si...

متن کامل

Bridging Small-Gap Peripheral Nerve Defect Using Silicone Rubber Chamber in the Rat Sciatic Nerve Transection Model

  Despite promising results observed using silicone rubber chamber, no previous comprehensive work was performed on behavior of the conduit. Present study aimed at further functional, histomorphometrical and immunohistochemical assessment of nerve regeneration in the same animal along a 10-mm rat sciatic nerve gap. Fifty- four male Wistar rats were divided into three experimental groups (n = 1...

متن کامل

Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study

Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...

متن کامل

Biofilm formation on silicone tympanostomy tubes with polyvinylpyrrolidone coating.

OBJECTIVE To determine whether biofilm formation on silicone tympanostomy tubes (TTs) is prevented by polyvinylpyrrolidone (PVP) coating. DESIGN In vitro microbiologic study. SUBJECTS Silicone TTs with and without a PVP coating. INTERVENTION The TTs were exposed to blood or phosphate-buffered saline and cultured with Pseudomonas aeruginosa or Staphylococcus aureus. After 4 days, antibioti...

متن کامل

Identifying the Optimal Water-Occluding Earplugs: A Scientific Simulation Study.

OBJECTIVE Numerous types of water-occluding earplugs are available as a means of preventing infection in patients with external and middle ear disease. However, little is known about the comparative efficacies of these earplugs with prolonged water exposure. In this study, we assessed the water impermeability of various earplug materials to prolonged water exposure. MATERIALS AND METHODS Nine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 82 12  شماره 

صفحات  -

تاریخ انتشار 1998