Comparison of ⁹⁰Y and ¹⁷⁷Lu measurement capability in UK and European hospitals.

نویسندگان

  • Andrew Fenwick
  • Michaela Baker
  • Kelley Ferreira
  • John Keightley
چکیده

Comparison exercises involving (90)Y and (177)Lu were performed during 2009 and 2012, respectively, to assess the measurement capability of hospitals in the UK and Europe. The results from the measurement of a typical liquid solution of (90)Y show that only 40% of participants could measure the solution to within 5% of the certificated value and that a significant -6% bias was present due to the use of non-standard geometries for the calibration of equipment. The results from the measurement of a standard liquid solution of (177)Lu show that 81% of participants could measure to within 5% of the certificated value and in fact 65% of these results were within 2% of the certificated value, showing administered activities can be far more accurately measured for (177)Lu than for (90)Y and that (177)Lu has a far smaller geometry dependence. These studies were performed to identify specific measurement issues in the user community and to identify areas where future research should be focused. In addition to this the work allows the participants to adjust measurement practice and identify key measurement issues.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

سنجش سطح قابلیت‌های یادگیری سازمانی در بیمارستانها

In the organizational studies, the measurement of organizational learning capabilities has become an increasingly important area. There are several models in literature that have been generated by statistical data from manufacturing firms. In this paper we have used a structural equation model for measurement of organizational learning in hospitals as services firms. In our model, there are fou...

متن کامل

Dosimetric analysis for the selection of radionuclides in bone pain palliation targeted therapy: A Monte Carlo simulation

Introduction:The use of beta emitters is one of the effective methods for palliation of bone metastasis. The risk of normal tissue toxicity should be evaluated in the bone pain palliation treatment. Methods: In this study, the Monte Carlo simulation code MCNPX was used for simulation a bone phantom model consisted of bone marrow, bone and soft tissue. Spe...

متن کامل

UK and Twenty Comparable Countries GDP-Expenditure-on-Health 1980-2013: The Historic and Continued Low Priority of UK Health-Related Expenditure

It is well-established that for a considerable period the United Kingdom has spent proportionally less of its gross domestic product (GDP) on health-related services than almost any other comparable country. Average European spending on health (as a % of GDP) in the period 1980 to 2013 has been 19% higher than the United Kingdom, indicating that comparable countries give far greater fiscal prio...

متن کامل

Employee Engagement within the NHS: A Cross-Sectional Study

Background Employee engagement is the emotional commitment of the employee towards the organisation. We aimed to analyse baseline work engagement using Utrecht Work Engagement Scale (UWES) at a teaching hospital.   Methods We have conducted a cross-sectional study within the National Health Service (NHS) Teaching Hospital in the UK. All participants were working age population from both genders...

متن کامل

The Effect of Gauge Measurement Capability and Dependency Measure of Process Variables on the MCp

It has been proved that process capability indices provide very efficient measures of the capability of processes from many different perspectives. These indices have been widely used in the manufacturing industry for measuring process reproduction capability according to manufacturing specifications. In the past few years, univariate capability indices have been introduced and used to characte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 87  شماره 

صفحات  -

تاریخ انتشار 2014