Sensitivity enhancement for colorimetric glucose assays on whole blood by on-chip beam-guidance.
نویسندگان
چکیده
In this paper, we present a novel concept for optical beam-guidance to significantly enhance the sensitivity of colorimetric assays by extending the optical path length through the detection cell which linearly impacts the resulting attenuation of a probe beam according to the law of Beer-Lambert. In our setup, the incident probe beam is deflected by 90( composite function) into the chip plane at monolithically integrated V-grooves to pass a flat detection cell at its full width (i.e., with a path length of 10 mm) instead of its usually much smaller height. Afterwards, the attenuated beam is redirected by another V-groove towards an external detector. The general beam-guidance concept is demonstrated by a glucose assay on human whole blood on a centrifugal microfluidic "lab-on-a-disk" platform made of COC. We achieve an excellent linearity with a correlation coefficient (R (2)) of 0.997 paired with a lower limit of detection (200 microM) and a good reproducibility with a coefficient of variation (CV) of 4.0% over nearly three orders of magnitude. With an accelerated sedimentation of cellular constituents by centrifugal forces, the sample of whole blood can be analyzed in a fully integrated fashion within 210 s. This time-to-result can even be improved by the numerical extrapolation of the saturation value. Additionally, the direct assay on whole blood also shows a negligible correlation with the hematocrit of the blood sample.
منابع مشابه
Battery operated preconcentration-assisted lateral flow assay.
Paper-based analytical devices (e.g. lateral flow assays) are highly advantageous as portable diagnostic systems owing to their low costs and ease of use. Because of their low sensitivity and detection limits for biomolecules, these devices have several limitations in applications for real-field diagnosis. Here, we demonstrate a paper-based preconcentration enhanced lateral flow assay using a c...
متن کاملSensitivity Enhancement of Fiber Optic Diesel Adulteration Detection Sensor Using Stripped Clad SBend Section
A novel geometry for enhancing the sensitivity of intensity modulated refractometric fiber optic sensor for detection of adulteration level in diesel by kerosene is proposed. In this multimode plastic optical fiber is uncladded for specific length and bent into S shape. This geometry is simulated and analyzed using Beam Propagation Method in Beam prop RSOFT software. When sensor is immersed in ...
متن کاملA novel wireless paper-based potentiometric platform for monitoring glucose in blood.
A novel low-cost, compact and sensitive paper-based platform for the accurate monitoring of glucose in biological fluids is presented. Paper-based working and reference electrodes are combined to build a whole potentiometric cell, which also fits a sampling module for simple and fast determination of glucose in a single drop of blood. The working electrode is built using a platinized filter pap...
متن کاملA siphonage flow and thread-based low-cost platform enables quantitative and sensitive assays.
For pump-free, material abundant, portable, and easy-to-operate low-cost microfluidics, a siphonage flow microfluidic thread-based analytical device (S-μTAD) platform enabling quantitative and sensitive assays was designed. Renewable and continuous siphonage flow allowed replicate sampling and detection on one channel/device, obviating some possible inconsistencies among channels or devices. Y-...
متن کاملDVD technology-based molecular diagnosis platform: quantitative pregnancy test on a disc.
A diagnosis platform based entirely on DVD technology was developed for on-site quantitation of molecular analytes of interest, e.g., human chorionic gonadotropin (hCG) in urine samples ("quantitative pregnancy test on a disc"). An hCG-specific monoclonal antibody-binding assay prepared on a regular DVD-R was labeled with nanogold-streptavidin conjugates for signal enhancement with a customized...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical microdevices
دوره 8 3 شماره
صفحات -
تاریخ انتشار 2006