Helical Centerline Stent Improves Patency

نویسندگان

  • Thomas Zeller
  • Peter A. Gaines
  • Gary M. Ansel
  • G. Caro
چکیده

Peripheral arterial disease (PAD) is common and expensive; in the United States alone, Medicare-funded inpatient costs in 2001 were estimated at $4.4 billion. The superficial femoral artery (SFA) is the most frequently involved segment in symptomatic PAD, irrespective of sex or race. Although endovascular intervention in the SFA is generally considered safe and efficacious, simple angioplasty has a poor outcome in the majority of patients. In a review of the outcome in the angioplasty control arm of 3 femoropopliteal stenting studies that resulted in Food and Drug Administration approval, the 12-month vessel patency after angioplasty of lesions 4to 15-cm long was only 28%. Initial attempts to improve outcome using nondedicated stents proved futile. Although contemporary dedicated nitinol stents have shown benefit over simple angioplasty and are now widely used to treat occlusive disease of the femoropopliteal artery, the 12-month patency remains far from ideal. Furthermore, when drug-coated balloons are used primarily to treat disease in this area, there will still be a need for stents to treat suboptimal results. Arterial geometry is commonly helical, generating swirling flow, which is known to elevate wall shear. Atherosclerosis and intimal hyperplasia (IH) mainly occur at locations where wall shear is low. A stent that can deform the vessel centerline into a helix has previously been demonstrated in a porcine model to reduce neointimal hyperplasia through mechanisms, including the elevation of wall shear. The purpose of the Mimics trial was to evaluate the safety and effectiveness of the BioMimics 3D helical stent (Veryan Medical Ltd, Horsham, United Kingdom) in the treatment of symptomatic PAD affecting the femoropopliteal artery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Helical CT angiography of fenestrated stent grafting of abdominal aortic aneurysms

Fenestrated stent grafts have been developed to treat patients with abdominal aortic aneurysms (AAA) associated with complicated aneurysm necks, such as short necks, severe angulated or poor quality necks (presence of calcification or thrombus). The technique is performed by creating an opening in the graft material so that the stent graft can be placed above the renal and other visceral branch...

متن کامل

Stent placement versus angioplasty improves patency of arteriovenous grafts and blood flow of arteriovenous fistulae.

BACKGROUND While endovascular stent placement is the standard of care in most percutaneous coronary and peripheral artery intervention, its role in the salvage of thrombosed and stenotic hemodialysis access remains controversial. DESIGN, SETTING, PARTICIPANTS, AND MEASUREMENTS We compared the effects of stent versus angioplasty on primary patency rates in the treatment of stenotic arterioveno...

متن کامل

Percutaneous Intraductal Radiofrequency Ablation Combined with Biliary Stent Placement for Nonresectable Malignant Biliary Obstruction Improves Stent Patency but not Survival

Although radiofrequency (RF) ablation has been accepted as a curative treatment modality for solid organ tumors, intraductal RF ablation for malignant biliary obstruction has not been widely described. The aim of this study was to evaluate the feasibility, safety, and efficacy (in terms of stent patency and survival) of intraductal RF ablation combined with biliary stent placement for nonresect...

متن کامل

Optimizing Strategy in Peripheral Vascular Interventions: The Role of JETSTREAM Atherectomy

Infrainguinal interventions remain challenging to endovascular specialists. Treatment of the femoropopliteal (FP) artery represents approximately 40% of all infrainguinal interventions. The FP artery is subject to multiple external forces. The use of selfexpanding nitinol stents in this vessel modestly improves patency but is associated with several potential problems including stent fracture, ...

متن کامل

Patency and clinical outcomes of transjugular intrahepatic portosystemic shunt with polytetrafluoroethylene-covered stents versus bare stents: a meta-analysis.

BACKGROUND AND AIM  Transjugular intrahepatic portosystemic shunt (TIPS) with polytetrafluoroethylene-(PTFE)-covered stent has been increasingly used for patients with complications of portal hypertension. It is still debated whether the new endoprostheses will improve some clinical outcomes (except for shunt patency) compared to the bare stents. The aims of our meta-analysis were to explore th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016