Stent boost enhancement compared to intravascular ultrasound in the evaluation of stent expansion in elective percutaneous coronary interventions

نویسندگان

  • Mohamed Laimoud
  • Yasser Nassar
  • Walid Omar
  • Akram Abdelbarry
  • Helmy Elghawaby
چکیده

Background Stent underexpansion is a major risk factor for in-stent restenosis and acute in-stent thrombosis1Intravascular ultrasound (IVUS) is one of the standards for detection of stent underexpansion (de Feyter et al. 1999; Mintz et al., 2001). StentBoost (SB) enhancement allows an improved angiographic visualization of the stent (Koolen et al., 2005). Aim of work Comparison of stent expansion by IVUS and SB enhancement and detection of value of SB to guide dilatation post stent deployment. Methodology IVUS, SB enhancement and QCA were done in 30 patients admitted for elective stenting procedures .We compared measurements of mean ±standard deviations of (Max SD, Min SD, Mean SD, stent symmetry index) using IVUS, SB and QCA after stent deployment and after postdilatation whenever necessary to optimize stent deployment. The Stent symmetry index was calculated [(maximum stent diameter minus minimum stent diameter) divided by maximum stent diameter]. Results The Max SD was (3.45 ± 0.62 vs 3.55 ± 0.56 vs 2.97 ± 0.59) by IVUS vs SB vs QCA respectively. Max SD was significantly higher by IVUS vs QCA (p .009) and between SB vs QCA (p .001) while there was nonsignificant difference between IVUS vs SB (p .53). The Min SD was (2.77 ± 0.53 vs 2.58 ± 0.56 vs 1.88 ± 0.60) by IVUS vs SB vs QCA respectively. Min SD was significantly higher by IVUS vs QCA (p .001) and between SB vs QCA (p .001) while there was nonsignificant difference between IVUS vs SB (p .07). The stent symmetry index was (0.24 ±0.09 vs 0.34 ± 0.09 vs 0.14 ±0.27) by IVUS vs SB vs QCA respectively. It was significantly higher by IVUS vs QCA (p .001) and between SB vs QCA (p .001) while there was nonsignificant difference between IVUS vs SB (p .32). SB was positively correlated with IVUS measurements of Max SD (p < .0001 & r 0.74) and Min SD (p < .0001 & r 0.68). QCA was positively correlated with IVUS measurements of Max SD correlation (p < .0001 & r 0.69) and Min SD (p < .0001 & r 0.63). QCA was positively correlated with SB measurements of Max SD (p < .0001 & r 0.61) and Min SD (p .003 & r 0.49). Conclusions StentBoost enhancement has superior correlations for stent expansion measured by IVUS when compared with QCA. SB enhancement improved stent visualization and identification of stent underexpansion to guide stent postdilatation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

StentBoost Visualization for the Evaluation of Coronary Stent Expansion During Percutaneous Coronary Interventions

INTRODUCTION Inadequate stent implantation is associated with stent thrombosis and restenosis. StentBoost can enhance stent visualization and evaluate stent expansion. Currently, there are limited comparison studies between StentBoost and intravascular ultrasound (IVUS). We aimed to test the correlation and agreement between IVUS and StentBoost measurements. METHODS From December 2010 to Dece...

متن کامل

A randomized controlled trial of angiography versus intravascular ultrasound-directed bare-metal coronary stent placement (the AVID Trial).

BACKGROUND AVID (Angiography Versus Intravascular ultrasound-Directed stent placement) is a multicenter, randomized controlled trial designed to assess the effect of intravascular ultrasound (IVUS)-directed stent placement on the 12-month rate of target lesion revascularization (TLR). METHODS AND RESULTS After elective coronary stent placement and an optimal angiographic result (<10% stenosis...

متن کامل

Prevalence, Features, and Prognostic Importance of Edge Dissection After Drug-Eluting Stent Implantation: An ADAPT-DES Intravascular Ultrasound Substudy.

BACKGROUND Intravascular ultrasound detects stent edge dissections after percutaneous coronary intervention that are not seen angiographically. This study investigated the association between stent edge dissections and clinical outcomes. METHODS AND RESULTS ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a large-scale, prospective, multicenter study of patient...

متن کامل

Observation of the expansion behavior and quantitative evaluation of elastic recoil of a balloon-expandable stent in three dimensions using a Micro-CT system.

Percutaneous transluminal coronary angioplasty (PTCA) with stent implantation is widely used for the treatment of coronary stenosis. However, restenosis after stent implantation frequently reported by intravascular ultrasound evaluation. This may occur because of the reduced luminal area after implantation, insufficient stent expansion, or by the elastic recoil of the stent (ERS). Quantitative ...

متن کامل

Volumetric intravascular ultrasound assessment of mechanisms and results of stent expansion in heart transplant patients.

BACKGROUND Percutaneous coronary intervention with stent placement for the treatment of patients with cardiac allograft vasculopathy is common, but data regarding stent behavior in this setting is lacking. OBJECTIVES We investigated mechanisms and potential differences in stent expansion among transplant patients vs. patients with native coronary artery atherosclerotic disease ("controls"). ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 70  شماره 

صفحات  -

تاریخ انتشار 2018