Corneal hysteresis and visual field asymmetry in open angle glaucoma.
نویسندگان
چکیده
PURPOSE To investigate the association between corneal biomechanical parameters and asymmetric primary open angle glaucoma (POAG) using the Ocular Response Analyzer (ORA). METHODS In a prospective cross-sectional study, ORA parameters were measured in 117 POAG patients with asymmetric visual fields (VF). The asymmetry in VF was defined as a five point difference between the eyes using the Advanced Glaucoma Intervention Study (AGIS) scoring system. Subjects with previous intraocular or refractive surgery, ocular comorbidities and diabetes were excluded. RESULTS In worse eyes, mean AGIS scores were significantly higher (8.1 ± 4.3 vs. 1.0 ± 1.6; P < 0.001) and mean corneal hysteresis (CH) was significantly lower (8.2 ± 1.9 vs. 8.9 ± 1.9 mm Hg; P < 0.001). Median ORA-corrected intraocular pressure was higher in the worse eyes (IOP(cc), 17.4 mm Hg vs. 16.9 mm Hg; P < 0.001). Worse eyes had a slightly lower mean corneal resistance factor (P = 0.04) and more myopic mean spherical equivalent (P = 0.02). No difference was seen in the central corneal thickness (CCT; P = 0.63) and Goldmann applanation tonometry (GAT; P = 0.32). On multivariate analysis, only CH retained an association with the worse eye (odds ratio, 25.9; 95% confidence interval, 10.1-66.5). ROC curves showed that only CH and IOP(cc) had a discriminative ability for the eye with worse VF (AUC, 0.82 and 0.70, respectively). CONCLUSIONS Asymmetric POAG was associated with asymmetry in ORA parameters but not in CCT and GAT. Lower CH was associated with worse eyes independently of its effect on IOP measurement and had the best discriminability for the eye with the worse VF.
منابع مشابه
Correlations between Corneal Biomechanics and Glaucoma Severity in Patients with Primary Open Angle Glaucoma.
OBJECTIVES To investigate the relationship between corneal biomechanical changes and glaucoma severity in primary open angle glaucoma patients. DESIGN Correlation study. MATERIALS AND METHODS Our study included 70 glaucomatous eyes; they were divided in groups using Glaucoma Staging System Based on Humphrey Visual Field. Ocular Response Analyzer (ORA) was used in order to determine corneal ...
متن کاملErratum. Lack of Association Between Corneal Hysteresis and Corneal Resistance Factor With Glaucoma Severity in Primary Angle Closure Glaucoma.
PURPOSE We investigated the association between corneal hysteresis (CH) and corneal resistance factor (CRF) with glaucoma severity in primary angle closure glaucoma (PACG). METHODS We recruited 204 subjects with PACG. Each subject underwent CH and CRF measurements using the Ocular Response Analyzer (ORA), optic nerve head topography measurement using scanning laser ophthalmoscopy, and visual ...
متن کاملAssociation between Corneal Biomechanical Properties with Ocular Response Analyzer and Also CorvisST Tonometry, and Glaucomatous Visual Field Severity
PURPOSE To investigate the association between corneal biomechanical properties measured with the Ocular Response Analyzer (ORA) and also CorvisST (CST) tonometry, and glaucomatous visual field (VF) severity. METHODS One hundred forty-six eyes of 91 patients with primary open-angle glaucoma who performed Humphrey Field Analyzer 30-2 or 24-2 SITA-Standard, ORA, and CST within 180 days were inc...
متن کاملCentral corneal pachymetry and visual field progression in patients with open-angle glaucoma.
PURPOSE To investigate the association between corneal pachymetry and visual field progression in patients with chronic open-angle glaucoma. DESIGN Retrospective case-control study. PARTICIPANTS Eighty-eight patients with primary open-angle glaucoma, pseudoexfoliative glaucoma, pigmentary glaucoma, or normal-tension glaucoma, followed for an average of 8 years, who had visual field loss and...
متن کاملThe role of corneal hysteresis during the evaluation of patients with possible normal-tension glaucoma
Purpose There are multiple reports of the role of corneal hysteresis (CH) as an independent risk factor for the diagnosis and risk of progression of normal-tension glaucoma (NTG). Our study measured CH with the Ocular Response Analyzer (ORA) in patients with intraocular pressure (IOP) <21 mmHg to investigate if a low CH would identify NTG in this Asian-based practice. Methods This was a prosp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 51 12 شماره
صفحات -
تاریخ انتشار 2010