Enhanced MALDI-TOF MS Analysis of Phosphopeptides Using an Optimized DHAP/DAHC Matrix

نویسندگان

  • Junjie Hou
  • Zhensheng Xie
  • Peng Xue
  • Ziyou Cui
  • Xiulan Chen
  • Jing Li
  • Tanxi Cai
  • Peng Wu
  • Fuquan Yang
چکیده

Selecting an appropriate matrix solution is one of the most effective means of increasing the ionization efficiency of phosphopeptides in matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In this study, we systematically assessed matrix combinations of 2, 6-dihydroxyacetophenone (DHAP) and diammonium hydrogen citrate (DAHC), and demonstrated that the low ratio DHAP/DAHC matrix was more effective in enhancing the ionization of phosphopeptides. Low femtomole level of phosphopeptides from the tryptic digests of alpha-casein and beta-casein was readily detected by MALDI-TOF-MS in both positive and negative ion mode without desalination or phosphopeptide enrichment. Compared with the DHB/PA matrix, the optimized DHAP/DAHC matrix yielded superior sample homogeneity and higher phosphopeptide measurement sensitivity, particularly when multiple phosphorylated peptides were assessed. Finally, the DHAP/DAHC matrix was applied to identify phosphorylation sites from alpha-casein and beta-casein and to characterize two phosphorylation sites from the human histone H1 treated with Cyclin-Dependent Kinase-1 (CDK1) by MALDI-TOF/TOF MS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nanodiamond-based two-step sampling of multiply and singly phosphorylated peptides for MALDI-TOF mass spectrometry analysis.

Simultaneous detection of multiply and singly phosphorylated peptides using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is challenging because of suppression effects during ionization. In oder to overcome this problem, this study presents a new approach to improve the detection of phosphopeptides by stepwise enrichment using polyarginine-coated (P...

متن کامل

A Novel Strategy for the Analysis of Phosphopeptides, Coupling N-terminal Peptide Derivatization and Hplc Separation with Mass Spectrometry

• Here we present an N-terminal derivatization approach, using TMPP-Ac-Osu that improves the HPLC performance for small hydrophilic phosphopeptides. • This approach is compatible with LC/MS and LC/MALDI. • The chromatographic enhancement was evaluated by on-line nanoscale HPLC coupled with Electrospray on a Q-Tof PremierTM. • LC-MALDI/MS/MS analysis was also investigated. Both MS/MS on a Q-Tof ...

متن کامل

Detecting the Site of Phosphorylation in Phosphopeptides Without Loss of Phosphate Group Using MALDI TOF Mass Spectrometry

Phosphopeptides with one and four phosphate groups were characterized by MALDI mass spectrometry. The molecular ion of monophosphopeptide could be detected both as positive and negative ions by MALDI TOF with delayed extraction (DE) and in the reflector mode. The tetraphospho peptide could be detected in linear mode. When MS/MS spectra of the monophospho peptides were obtained in a MALDI TOF TO...

متن کامل

One-pot synthesis of dopamine dithiocarbamate functionalized gold nanoparticles for quantitative analysis of small molecules and phosphopeptides in SALDI- and MALDI-MS.

The sensitivity and efficiency of SALDI-MS or MALDI-MS is mainly dependent on the nature of matrix. A novel approach is proposed for one-pot synthesis of dopamine dithiocarbamate-functionalized gold nanoparticles (DDTC-Au NPs). Their application to quantification of small molecules by surface assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI-TOF-MS) and rapid identifi...

متن کامل

Inhibitor screening of protein kinases using MALDI-TOF MS combined with separation and enrichment of phosphopeptides by TiO2 nanoparticle deposited capillary column.

A MALDI-TOF mass spectrometric method for rapid screening of protein tyrosine kinase (PTK) inhibitors has been developed. To circumvent the ion suppression of phosphorylated substrate peptides caused by the presence of high abundant non-phosphorylated peptides in the enzymatic reaction mixtures, a separation and enrichment process of the phosphorylated peptides from complex mixtures was carried...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2010  شماره 

صفحات  -

تاریخ انتشار 2010