BACKGROUND The aim of this study was to demonstrate the technical feasibility and potential benefits of using a circular mechanical stapler with free jejunal transfer for jejunoesophageal anastomosis in total laryngopharyngectomy reconstruction while comparing the rates of fistula and stricture. METHODS This study was a retrospective review of 12 free jejunal flaps completed with circular mechanical stapler for the jejunoesophageal anastomosis with comparison to 17 jejunal free flaps where all anastomoses were hand sewn. RESULTS In all, 29 patients underwent free jejunal transfer: 12 had jejunal free flap with circular mechanical stapler for jejunoesophageal anastomosis, whereas 17 patients had hand-sewn anastomosis. Corresponding rates of fistula and stricture were 0/12 fistulas and 3/12 strictures in the stapler cohort and 2/17 fistulas with 0/17 strictures in the hand-sewn cohort. No statistically significant difference in rate of fistula was observed between each cohort, whereas a trend toward increased rate of stricture (p = .06) was observed in the stapled anastomosis cohort. CONCLUSIONS Use of circular mechanical stapler appears to be a safe and effective technique at the jejunoesophageal anastomosis for total laryngopharyngeal defects with comparable fistula and stricture rates to grafts that are hand sewn.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Study of Hand-Sutured versus Circular Stapled Anastomosis for Gastrojejunostomy in Laparoscopy Assisted Distal Gastrectomy

PURPOSE Mechanical stapler is regarded as a good alternative to the hand sewing technique, when used in gastric reconstruction. The circular stapling method has been widely applied to gastrectomy (open orlaparoscopic), for gastric cancer. We illustrated and compared the hand-sutured method to the circular stapling method, for Billroth-II, in patients who underwent laparoscopy assisted distal ga...

متن کامل

Total mechanical stapled oesophagogastric anastomosis on the neck in oesophageal cancer – prevention of postoperative mediastinal complications

Oesophagogastric anastomosis after oesophagus resection is commonly performed on the neck. Even though a few different techniques of oesophagogastric anastomosis have been previously detailed, both manual and mechanical procedures have been burdened with leakages and strictures. Our simple technique of oesophagogastric anastomosis is a modification of mechanical anastomosis with the use of a ci...

متن کامل

Minimum leakage rate (0.5%) of stapled esophagojejunostomy with sacrifice of a small part of the jejunum after total gastrectomy in 390 consecutive patients.

BACKGROUND The development of new surgical instruments and devices has facilitated the performance of esophagojejunostomy after total gastrectomy. However, total prevention of dehiscence of anastomoses remains difficult. We introduced a new procedure for esophagojejunostomy using a circular stapler, requiring sacrifice of only a small part of the jejunum. METHODS The study group comprised 390...

متن کامل

Risk factors associated with delayed gastric emptying after subtotal gastrectomy with Billroth-I anastomosis using circular stapler for early gastric cancer patients

PURPOSE Gastric surgery may potentiate delayed gastric emptying. Billroth I gastroduodenostomy using a circular stapler is the most preferable reconstruction method. The purpose of this study is to analyze the risk factors associated with delayed gastric emptying after radical subtotal gastrectomy with Billroth I anastomosis using a stapler for early gastric cancer. METHODS Three hundred and ...

متن کامل

Usefulness of automatic triangular anastomosis for esophageal cancer surgery using a linear stapler (TA-30).

In a clinical evaluation, thirty-one patients with thoracic esophageal cancer who were treated from 1997 to 2000 were selected as subjects including those who underwent hand sewn anastomosis method, circular stapler method and triangular anastomosis method. Incidence of anastomosis failure was 27.3%, 25.0% and 8.3% for the hand sewn anastomosis method, circular stapler method and triangular ana...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Head & neck

دوره 34 5  شماره 

صفحات  -

تاریخ انتشار 2012