Valve-in-valve implantation of Medtronic CoreValve prosthesis in patients with failing bioprosthetic aortic valves.

نویسندگان

  • Axel Linke
  • Felix Woitek
  • Marc W Merx
  • Conrad Schiefer
  • Sven Möbius-Winkler
  • David Holzhey
  • Ardawan Rastan
  • Jörg Ender
  • Thomas Walther
  • Malte Kelm
  • Friedrich W Mohr
  • Gerhard Schuler
چکیده

BACKGROUND Transcatheter aortic valve implantation (TAVI) using the Medtronic CoreValve (MCV) system might represent an alternative to conventional redo surgery in older high-risk patients with a failing aortic valve bioprosthesis. METHODS AND RESULTS Symptomatic patients with failing aortic valve bioprosthesis, aged ≥65 years with a logistic EuroSCORE ≥10 % were considered for treatment. Local anesthesia was used to retrogradely implant the MCV system into the failing bioprosthetic valve. Clinical events were recorded and a transthoracic echocardiography was performed to evaluate the impact of MCV on hemodynamics after transcatheter aortic valve implantation. A total of 27 patients (aged 74.8±8 years, logistic EuroSCORE of 31±17%) were treated. In those with AS and AS and AR (n=25), the mean gradient declined from 42±16 mm Hg before to 18±8 mm Hg after MCV implantation (P<0.001), in those with AR the level declined by 2. There was no intraprocedural death and no procedural myocardial infarction. On the basis of the definitions of the Valvular Academic Research Consortium, the rate of major stroke was 7.4 %, of life-threatening bleeding 7.4%, of kidney failure stage III 7.4%, and of major access site complication 11.1 %, respectively. Within 30 days after the procedure, 2 patients died; 1 from stroke and 1 from cardiac failure (30-day mortality: 7.4%). CONCLUSIONS These results suggest that transfemoral mcv implantation into a wide range of degenerated aortic bioprosthetic valves - irrespective of the failure mode - is feasible, safe, and improves hemodynamics in older patients with higher risk for conventional aortic valve redo surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

Transcatheter aortic valve implantation for stenosed and regurgitant aortic valve bioprostheses CoreValve for failed bioprosthetic aortic valve replacements.

Transcatheter aortic valve implantation is increasingly being used to treat severe aortic stenosis in patients with high operative risk. In an aging population the incidence of aortic stenosis is rising, and increasing numbers of elderly patients are undergoing aortic valve replacement with bioprosthetic valves. Therefore, there is a corresponding increase in prosthetic degeneration. This prese...

متن کامل

Evolution in transcatheter aortic valve replacement: the CoreValve® self-expanding prosthetic aortic valve

Aortic stenosis is one of the more commonly encountered disease processes in valvular heart disease, affecting over 300,000 people worldwide. Surgical replacement of the aortic valve has been the mainstay of therapy for decades; however, in certain patients with prohibitively high-risk comorbidities, surgery is not a viable option. The advent of transcatheter aortic valve replacement has come t...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Evaluation of stentless kangaroo aortic valves in the mitral position of juvenile sheep.

BACKGROUND AND AIM OF THE STUDY The performance and longevity of bioprosthetic heart valves are limited by tissue calcification and degeneration after implantation. Experimental valve replacement in large animal models forms an important component of the preclinical evaluation of these bioprosthetic heart valves. The study aim was to assess the feasibility of a mitral model for stentless valves...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 5 5  شماره 

صفحات  -

تاریخ انتشار 2012