Indirect electroanalytical detection of phenols † Athanasios

نویسندگان

  • Athanasios V. Kolliopoulos
  • Dimitrios K. Kampouris
  • Craig E. Banks
چکیده

A novel indirect electrochemical protocol for the electroanalytical detection of phenols is presented for the first time. This methodology is demonstrated with the indirect determination of the target analytes phenol, 2-chlorophenol, 4-chlorophenol and 2,4-dichlorophenol through an electrochemically adapted optical protocol. This electrochemical adaptation allows the determination of the above mentioned phenols without the use of any oxidising agents, as is the case in the optical method, where pyrazoline compounds (mediators) chemically react with the target phenols forming a quinoneimine product which is electrochemically active providing an indirect analytical signal to measure the target phenol(s). A range of commercially available pyrazoline substitution products, namely 4-dimethylaminoantipyrine, antipyrine, 3-methyl-1-(2-phenylethyl)-2-pyrazolin-5-one, 3-amino-1-(1-naphthylmethyl)-2-Pyrazolin-5-one, 4-amino-1,2-dimethyl-3-pentadecyl-3-pyrazolin-5-one hydrochloride, 3-amino-1-(2-amino-4-methylsulfonylphenyl)-2-pyrazolin-5-one hydrochloride and 4-aminoantipyrine are evaluated as mediators for the indirect detection of phenols. The indirect electrochemical detection of phenol, 2-chlorophenol, 4-chlorophenol and 2,4-dichlorophenol through the use of 4-aminoantipyrine as a mediator are successfully determined in drinking water samples at analytically useful levels. Finally, the comparison of the direct (no mediator) and the proposed indirect determination (with 4-aminoantipyrine) towards the analytical detection of the target phenols in drinking water is presented. The limitation of the proposed electroanalytical protocol is quantified for all the four target phenols.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indirect electroanalytical detection of phenols.

A novel indirect electrochemical protocol for the electroanalytical detection of phenols is presented for the first time. This methodology is demonstrated with the indirect determination of the target analytes phenol, 2-chlorophenol, 4-chlorophenol and 2,4-dichlorophenol through an electrochemically adapted optical protocol. This electrochemical adaptation allows the determination of the above ...

متن کامل

Electrochemical Analysis of Organic Pollutants

The electroanalytical techniques of pulse polarography, stripping voltammetry and on-line electrochemical detection have been used for the identification and determination of trace concentrations of a wide variety of environmentally significant organic molecules, usually after the application of sample pretreatment procedures, certain separation techniques and, in some cases, derivatisation. Cl...

متن کامل

Screen-printed back-to-back electroanalytical sensors: heavy metal ion sensing.

Screen-printed back-to-back microband electroanalytical sensors are applied to the quantification of lead(II) ions for the first time. In this configuration the electrodes are positioned back-to-back with a common electrical connection to the two working electrodes with the counter and reference electrodes for each connected in the same manner as a normal "traditional" screen-printed sensor. Pr...

متن کامل

Electroanalytical sensing of Asulam based on nanocomposite modified glassy carbon electrode

In this study a facile approach to employ Copper nanoparticle (CuNPs) and multi-walled carbon nanotubes (MWCNT) as the nanomaterial for selective detection of asulam have been investigated. This work reports the electrocatalytic oxidation of asulam on glassy carbon electrodes (GCE) modified with multi-walled carbon nanotubes (MWCNT), ionic liquids (IL), chitosan (Chit) and copper nanoparticles ...

متن کامل

Ion-exchange voltammetry at polymer film-coated nanoelectrode ensembles.

Ensembles of nanoscopic disk-shaped electrodes have been shown to offer enhancements in electroanalytical detection limits relative to electrodes of macroscopic dimensions (e.g., disk electrodes with diameters of ∼1 mm). Enhancements in electroanalytical detection limits have also been observed at macroscopic electrodes that have been coated with films of ion-exchange polymers. In this paper we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015