An obstructive, proximally migrated plastic biliary stent extracted with a "modified" Seldinger technique and a polypectomy snare.

نویسندگان

  • B Mangiavillano
  • E Masci
چکیده

ted, plastic biliary stents may be techni− cally challenging and sometimes unsuc− cessful [1]. Data from the literature report a retrieval success rate of 85%, with the remaining 15% requiring surgical removal [2]. The choice of retrieval technique is dependent on several factors, including biliary ductal dilatation, depth of stent migration, distal stent impaction, and biliary stricture distal to the migrated stent. The placement of an additional stent alongside an irretrievable stent has been reported as an alternative technique to retrieval, but the risk of cholangitis associated with this technique is not yet widely known by practitioners [3]. De− spite the widespread use of such stents, there are few reports on the technique and the different accessories available for retrieval of migrated stents. Furthermore, there are no reports in the literature on proximally migrated, biliary stent remov− al using a polypectomy snare. A 53−year−old man with a history of chronic pancreatitis underwent endo− scopic retrograde cholangiopancreato− graphy (ERCP) with biliary stent insertion in September 2006, for distal common bile duct benign stenosis. On November 2006 he was referred to our center after developing cholangitis. An ERCP was car− ried out, and the abdominal pre−proce− dural radiograph showed a proximal mi− gration of the biliary stent. Different tech− niques were utilized to retrieve the stent (Dormia basket, forceps, balloon, Sohen− dra extractor), but all of them failed. It was not possible to insert a guide wire into the distal orifice of the stent because the angulated distal part of the stent was too close to the biliary wall. With a sphincterotome, which allowed us to ad− dress the direction, a wire was inserted through the distal flap−hole, and into the stent ( l" Fig. 1). Over the wire, a polypec− tomy snare was placed as far as the distal edge of the stent and then opened, thus catching the stent ( l" Fig. 2). The stent was then successfully removed (l" Fig. 3). Endoscopy_UCTN_Code_TTT_1AR_2AZ

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biliary Stent Migration to Hepatic Duct–Case Report of a Late Complication

Endoscopic retrieval of proximally migrated biliary plastic stents may be technically challenging and sometimes unsuccessful. Here we report the case of a 59-year-old woman with a migrated biliary stent in the right hepatic duct, which was diagnosed after the patient presented with cholangitis. The patient presented with constant abdominal pain in the right upper quadrant lasting for two days, ...

متن کامل

Snare-over-scope technique for retrieval of a proximally migrated biliary stent.

of a proximally migrated biliary stent There is no consensus on the optimal technique for retrieval of proximally migrated biliary stents. A biliary sphincterotomy or sphincteroplasty, together with the use of accessories such as stentgrasping forceps, Soehendra stent retrieval device, and stone extraction balloon, have been reported [1–4]. We present the case of a proximally migrated biliary s...

متن کامل

Endoscopic retrieval of a proximally migrated pancreatic stent: variation of the lasso technique.

retrieve proximally migrated pancreatic stents [1,2]. The lasso technique involves inserting a guide wire through the lumen of the migrated stent followed by insertion of a partially opened polypectomy snare over the wire to grasp the stent [3]. We present the case of a 72-year-old woman with recurrent acute biliary pancreatitis, who underwent endoscopic retrograde cholangiopancreatography (ERC...

متن کامل

Endoscopic removal of a proximally migrated biliary stent using a novel gooseneck snare: the "EndoCowboy".

Proximal migration often occurs as an adverse event of biliary stent placement, with a reported migration rate of 3.1%– 4.9% [1]. Although various techniques have been reported for endoscopic removal of proximally migrated biliary stents, the procedure is still technically demanding and time-consuming, and occasionally unsuccessful [2–4]. We describe a useful technique for endoscopic removal of...

متن کامل

Endoscopic retrieval of a proximally migrated biliary plastic stent using a guidewire loop technique.

Endoscopic biliary stent placement is a well-established technique for various indications including biliary drainage. However, it has been shown that approximately 5% of plastic stents placed in the biliary tract migrate proximally [1]. Endoscopic retrieval of proximally migrated biliary stents is technically challenging and occasionally unsuccessful. Several techniques for retrieving proximal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endoscopy

دوره 39 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2007