Heparin interferes with the radioenzymatic and homogeneous enzyme immunoassays for aminoglycosides.
نویسندگان
چکیده
Heparin interferes with measurement of aminoglycosides in serum by biological, radioenzymatic, and homogeneous enzyme immunoassay techniques, but not with radioimmunoassay. At concentrations greater than or equal to 10(5) and greater than or equal to 3 X 10(6) USP units/L, respectively, it interferes with the radioenzymatic assay by inhibiting the gentamicin 3-acetyltransferase (EC 2.3.1.60) and kanamycin 6'-acetyltransferase (EC 2.3.1.55) enzymes used in the assay. It interferes with the homogeneous enzyme immunoassays for gentamicin and tobramycin (at concentrations greater than or equal to 10(5) and greater than or equal to 10(4) USP units/L, respectively), but not with the commercially available homogeneous enzyme immunoassays for other drugs. Heparin interference with the homogeneous enzyme immunoassay for aminoglycosides requires both the heparin polyanion and glucose-6-phosphate dehydrogenase (EC 1.1.1.49) bound to a cationic aminoglycoside. This interference can be reproduced with dextran sulfate (but not dextran), and does not occur with free enzyme (glucose-6-phosphate dehydrogenase) alone. We describe how heparin interferes with these two assays and demonstrate interference at heparin concentrations that may be present in intravenous infusions or in seriously underfilled blood-collection tubes.
منابع مشابه
Improved acetylating radioenzymatic assay of amikacin, tobramycin, and sisomicin in serum.
The acetylating radioenzymatic assay of aminoglycosides was modified by using [(3)H]acetyl coenzyme A as cosubstrate. This modification reduces the cost of the method by at least one-half without sacrificing rapidity or accuracy.
متن کاملInhibition of aminoglycoside activity in heparin.
Measurements of aminoglycosides by an agar disk diffusion assay are inhibited by heparin in a dose-dependent way. When assayed by a homogeneous immunoassay, this was only evident for tobramycin. This indicates that specimens for aminoglycoside measurement should not be obtained in heparinized tubes. When heparin is used clinically as an anticoagulant, the amount in blood does not reach levels t...
متن کاملPrevalence of anti-HBc in HBsAg negative blood donors using two enzyme immunoassays kits
Abstract Background and Objectives Use of kits with high sensitivity and specificity to determine the prevalence of antibodies against hepatitis B virus (anti-HBc) core antigen is important. The aim of this study was to determine the prevalence of hepatitis B virus antibody in HBsAg negative blood donors using two anti-HBc enzyme immunoassay kits (DIA.PRO and SIEMENS). Materials and Methods...
متن کاملRadioimmunoassay and radioenzymatic assay of a new aminoglycoside antibiotic, netilmicin.
A radioimmunoassay and a radioenzymatic assay for netilmicin, a new aminoglycoside, were developed in our laboratories to assist in the study of the pharmacology of the drug and to establish values for use in its monitoring. The assays are sensitive, precise, and rapid, giving results that correlate (r = 0.90) with each other and with those of a microbiological assay in which Klebsiella pneumon...
متن کاملEvaluating heparin-induced thrombocytopenia: the old and the new.
Heparin-induced thrombocytopenia (HIT) is a rare but potentially serious complication of heparin use. Prompt diagnosis is crucial and requires the integration of clinical assessment and laboratory testing. Pretest clinical scoring systems (i.e., 4 Ts) have been established. Immunoassays can detect the presence of antibodies directed toward heparin-platelet factor 4 (H-PF4) complexes, but provid...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 28 7 شماره
صفحات -
تاریخ انتشار 1982